WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas supplies before servicing. Check appliance is safe when you have nished.
38
ArtNo.320-0020 Oven back fixing screws
5 Ovens
5.1 To Replace an Oven Thermostat
DISCONNECT FROM THE ELECTRICITY SUPPLY.
Remove the handrail (see 1.1), control panel (see 1.2)
and hotplate top (see 2.1). Open the oven doors and
remove the oven furniture.
Left-hand oven
From inside the oven remove the two screws holding
the thermostat phial to the oven fan cover at the rear of
the oven.
Remove the four screws that secure the fan cover
(Fig.9-5) then remove the fan cover.
Pull cooker forward to gain access to the cover box at
the rear of the cooker. Remove the screws securing the
cover and lift clear. The oven thermostat capillary is
clamped to the oven back sheet with an earthing plate.
Remove the screws and plate (Fig.9-6).
Remove the two screws securing the thermostat body
to the control panel at the front of the cooker. Remove
the assembly.
Fit new thermostat. Reassemble in reverse order.
Ensure that the phial is clipped to the oven back with
the phial centrally positioned between the clips.
Ensure that the thermostat capillary is clamped to the
oven back sheet with an earthing plate.
Check operation of thermostat.
Right-hand oven
From inside the oven remove the two screws holding
the thermostat phial to the oven fan cover at the rear of
the oven.
Remove the four screws that secure the fan cover
(Fig.9-5) then remove the fan cover.
The oven thermostat capillary is clamped to the right
hand rear upright with an earthing plate (Fig.9-6).
Remove the screws and plate.
Feed the thermostat capillary out of the oven.
Disconnect wiring from thermostat. Remove the two
screws holding thermostat to mounting panel. Fit new
thermostat and reassemble in reverse order.
Ensure that the phial is clipped to the oven back with
the phial centrally positioned between the clips.
Ensure that the thermostat capillary is clamped to the
right hand rear upright with an earthing plate.
Check operation of thermostat.
Thermostat capilary
Earthing plate
Fig.9-6