Loading ...
Loading ...
Loading ...
32
INSTALLATION
Check the appliance is electrically safe when you have nished.
Electrical Connection
This appliance must be installed by a qualied electrician
to comply with current AS/NZS 3000 Wiring Rules and
regulations in force.
Make sure that the mains characteristics (voltage, nominal,
power, etc.) match the ratings indicated on the data plate
axed to the cooker.
The cooker is preset for a single-phase earthed electrical
connection. It is essential to install a multi-pole circuit breaker
that completely disconnects the appliance from the mains,
with a minimum contact break distance of 3 mm.
Current Operated Earth Leakage Breakers
The combined use of your induction cooker and other
domestic appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
WARNING: THIS APPLIANCE MUST BE EARTHED.
The appliance must be connected to an ecient earthing
circuit. If the electricity network is not equipped with an
earth connection, then it must be installed separately in
compliance with local regulations.
Earthing is a safety measure required by law, and must be
performed with particular care by a qualied technician,
who must also check that the electricity supply
characteristics are correct.
The total electrical load of the appliance is approximately
14.5 kW. The cable size used should be suitable for this load
and comply with all local requirements (i.e. PVC Insulated
cable IEC 60227 – code 53 for ordinary cables).
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type (Fig. 7.11 and Fig. 7.12). Check that the links are
correctly tted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
An isolation switch shall be provided and mounted near
the cooker, in a readily accessible position, in compliance
with AS/NZS 3000.
ArtNo.132-0001 - 1 phase 240Vac 50Hz
1-phase 220-240 V
AC
50 Hz
Fig. 7.11
Fig. 7.12
Loading ...
Loading ...
Loading ...