11. Technical Data
This cooker is designed for use on Natural Gas, although a
conversion for LP (
LPG X Propane (2.54kPa)
) gas is available.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back. The serial number is repeated on the badge below the left-hand oven door opening.
Country of Destination: Australia
Test Pressures (quoted on the data badge)
Gas Electric
Natural gas 1kPa 240V 50Hz
Propane 2.54kPa
Dimensions
Overall height minimum 898mm maximum 925mm
Overall width 1100mm
Overall depth 648mm
Minimum space above hotplate 650mm
Connections
Gas Electric
Rp ½ at rear right 240V 50Hz
Ratings
Natural Gas 1.0kPa Propane 2.54kPa
Hotplate
Input
Injector Bypass
Input
Injector Bypass
Marking Size Ø Marking Marking Size Ø Marking
Wok burner
15MJh
-1
internal 112 1.12mm
90 15MJh
-1
internal 66 0.67mm
54
external 164 1.65mm external 91 0.87mm
Large Burner
12.3MJh
-1
165 1.65mm 80 12.3MJh
-1
89 0.96mm 41
Medium Burners
6.2MJh
-1
115 1.15mm 56 6.2MJh
-1
67 0.68mm 33
Small Burner
3.7MJh
-1
92 0.92mm 48 3.3MJh
-1
48 0.50mm 25
Gas burner inputs based on Gross Calorific Value
Ovens
Left-hand Multi-
function Oven
Right-hand Fan Oven
Fan element
2.72kW 2.72kW
Top element
1.3kW
Browning Element
1.25kW
Bottom element
1.1kW
Grill 2.5kW
Maximum total electrical load at 240V 8.06kW (approximate total including oven lights, oven fan, etc.).