WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
31
Set the Governor
Unscrew the governors brass top. In the base of the brass top
is a plastic snap-in converter device (Fig.8-4). To convert the
governor, snap the device out of the top and refit it the other
way round. The snap-in converter device is marked to show
the gas for which it is set (Fig.8-5).
Make sure the device is secure in the top cap and refit the cap
to the governor.
Affix Label
Stick the appropriate gas label over the natural gas part of the
appliance data label.
Ensure that the appliance is gas sound (refer to
‘Pressure Testing’ in the ‘Installation section).
Check the operation of all the burners.
ArtNo.102-0007 - Maxitrol converter device positions
Fig.8-5
ArtNo.103-0006 - Maxitrol cap & converter


Fig.8-4