LG Electronics LSCI307ST LG Studio - 30" Electric Induction Cooktop

User Manual - Page 25

For LSCI307ST.

PDF File Manual, 64 pages, Download pdf file

Loading ...
Loading ...
Loading ...
25
ENGLISH
INSTALLATION INSTRUCTIONS
IF COOKTOP IS USED IN A NEW BRANCH CIRCUIT INSTALLATION (1996 NEC), MOBILE
HOME, RECREATIONAL VEHICLE, OR WHERE LOCAL CODES DO NOT PERMIT
GROUNDING TO THE NEUTRAL (WHITE) WIRE
Observe all governing codes and local ordinances
.
Disconnect the power supply.
At the circuit breaker box, fuse box or junction
box, connect appliance and power supply cable
wires as shown.
1
Visually inspect the cooktop for damage. Make
sure all cooktop screws are tight (see below for
locations).
2
Carefully lower the cooktop into the countertop
cutout, making sure not to trap any wires.
NOTE: Do not use caulking compound. The
cooktop must be removable, should service be
required.
ELECTRICAL CONNECTIONS
(cont.)
COOKTOP INSTALLATION
WARNING
If connecting to a 4-wire power supply cable
electrical system, the appliance frame
connected ground wire MUST NOT be
connected to the neutral wire of the 4-wire
electrical system.
WARNING
Do not remove the nylon spacers on the
edges of the cooktop. These spacers center
the cooktop in the space provided. The
cooktop must be centered to allow proper
venting and to prevent excess heat buildup
that may result in heat damage or fire.
1
2
4-WIRE GROUNDED JUNCTION BOX
Green wire (ground)
Cable from cooktop
Screws
Nylon spacers
Cable from power supply
UL-listed conduit
connector
Junction box
Black
wires
White wire
(no connection)
Red
wires
Ground
wire
Loading ...
Loading ...
Loading ...