INSTALLATION INSTRUCTIONS
DIMENSIONS AND CLEARANCES
J
F
G
I
L
M
H
K
Overhead cabinet should not exceed a maximum
depth of 13” (33 cm).
Min. recommended
distance between
rear edge of cutout
and nearest
combustible
surface.
24"
(61 cm)
12"
(30.5 cm)
Min. from edge of
cooktop to nearest
combustible wall
(either side of unit).
30” (76.2 cm) min. clearance
between the top of the
cooktop and the bottom of
an unprotected wood or
metal cabinet.
24” (61 cm) min. when bottom
of wood or metal cabinet is
protected by not less than 1/8”
flame-retardant millboard
covered with no less than No.
28 MGS sheet steel, 0.015”
(0.4 mm) stainless steel,
0.024” (0.6 mm) aluminum, or
0.020” (0.5 mm) copper.
Empty space is needed underneath
the cooktop for installation purposes.
Approximate location of junction box.
18"
( 45.7 cm)
10"
( 25.4 cm)
Model H K
30ʺ 7
1
/2ʺ(191mm) 1
1
/2ʺ(38mm)
CAUTION
To eliminate the risk of burns or
fire by reaching over heated
surfaces, cabinet storage space
located above the cooktop
should be avoided. If cabinet
storage is provided, risk can be
reduced by installing a range
hood that projects horizontally a
minimum of 5ʺ (12.7 cm) beyond
the face of the cabinets.
CAUTION
It is very important to keep 2
3
/4” (70 mm)
distance between the cooktop and the oven.
Recommend space cooktop and oven
2
3
/4” (70 mm)
Loading ...