as connection
The gas inlet connection of the appliance has a “male thread.” When making the
connection, take care not to apply stresses of any kind to the appliance.
A
Gas Inlet
B Gasket
C
Gas installation
N
atural Gas: the supplied regulator must be fitted to the appliance inlet connection. Gas pressure must be
adjusted to 1.0 kPa when the auxiliary, semi rapid and rapid burners are set to high flame, the appliance
test point is located on the regulator.
LPG: the supplied test point adaptor must be fitted to the appliance inlet connection. Gas pressure must be
adjusted to 2.75 kPa, when the auxiliary, semi rapid and rapid burners are set to high flame, the appliance test
point is located on the test point adaptor.
When the installation is complete, always performance a gas leakage check that all the unions
are absolutely tight using a soapy solution. Never use a flame to make this check.