Loading ...
Loading ...
Loading ...
540mm Upright Cooker with GAS oven User manual
18
I
I
n
n
s
s
t
t
a
a
l
l
l
l
i
i
n
n
g
g
t
t
h
h
e
e
g
g
a
a
s
s
c
c
o
o
o
o
k
k
e
e
r
r
U
U
n
n
p
p
a
a
c
c
k
k
i
i
n
n
g
g
When packaging is removed from product you will notice there are several items nested in the packaging
base. The burner crowns, burner caps and trivets to be fitted to the hob.
N
N
o
o
t
t
e
e
T
T
h
h
a
a
t
t
W
W
o
o
k
k
t
t
r
r
i
i
v
v
e
e
t
t
i
i
s
s
a
a
d
d
i
i
f
f
f
f
e
e
r
r
e
e
n
n
t
t
s
s
i
i
z
z
e
e
a
a
n
n
d
d
m
m
u
u
s
s
t
t
b
b
e
e
c
c
o
o
r
r
r
r
e
e
c
c
t
t
l
l
y
y
l
l
o
o
c
c
a
a
t
t
e
e
d
d
o
o
v
v
e
e
r
r
W
W
o
o
k
k
b
b
u
u
r
r
n
n
e
e
r
r
.
.
L
L
o
o
c
c
a
a
t
t
i
i
n
n
g
g
t
t
h
h
e
e
c
c
o
o
o
o
k
k
e
e
r
r
This appliance must be installed by an authorised person in accordance with this instruction manual, AS/NZS
5601 – Gas installations (installation and pipe sizing), local gas fitting regulations, local electrical regulations,
local water regulations, local health regulations, Building Code of Australia and any other government
authority.
O
verhead clearances—(Measurement A)
Range hood
s
and exhaust fans shall be installed in accordance with the
manufacturer’s
relevant instructions. However, in no case shall the
clearance between the highest part of the
hob
of the
gas
cooking
appliance
and a
range hood
be less than 600 mm
or, for an overhead exhaust fan, 750 mm.
S
ide clearances(Measurements B, & C) Where B,
measured from the periphery of the nearest
burner
to
any vertical
combustible surface
, or vertical
combustible surface
covered with toughened glass or
sheet metal, is less than 200 mm, the surface shall be
protected to a height C of not less than 150 mm
above the
hob
for the full dimension (width or depth)
of the cooking surface area. Where the
gas
cooking
appliance
is fitted with a ‘splashback’, protection of
the rear wall is not required.
A
dditional requirements for freestanding and
e
levated gas cooking appliances— (Measurements
D
& E). Where D, the distance from the periphery of
the nearest burner to a horizontal combustible
surface is less than 200 mm, then E shall be 10 mm
or more, or the horizontal surface shall be above the
trivet.
G
G
a
a
s
s
t
t
y
y
p
p
e
e
Before installation check that the cooker is suitable for the gas supply. The cookers are manufactured for both
Natural gas or Universal LPG, check the gas type label located on appliance. If the cooker is required to be
converted to a different gas type, a conversion kit can be obtained by contacting the Customer Care Centre.
C
onnection to the gas supply
The isolating manual shut-off valve connection point must be installed and accessible when the appliance is in
position. Gas inlet is located at the top rear right hand side, 50mm from the edge. This appliance is suitable
for connection with rigid pipe or flexible hose. For flexible hose connection, the flexible hose assembly must
be certified to AS/NZS 1869 class B or D, be of appropriate internal diameter for the total gas consumption,
be kept as short as possible (not exceeding 1200mm), must not be in contact with the floor or any hot or
sharp surfaces. The hose assembly must not be subject to strain, abrasion, kinking or deformation.
Loading ...
Loading ...
Loading ...