32 33SPECIFICATIONSOUTDOOR INSTALLATION
OUTDOOR INSTALLATION INSTRUCTIONS
WARNING
WARNING
Contact your local municipality for any building codes
regulating the installation of outdoor barbecue appliances.
Outdoor installations must conform to local codes or, in the
absence of local codes, with the following.
We recommend that this installation be done in a masonry
structure and carried out by a professional tradesperson.
Other non-combustible material such as Hardiplank,
Villaboard with metal studs may also be used.
This appliance must not be installed under or on
any combustible material. Minimum clearance from
combustible construction materials to all sides of the
appliance is 450mm. Australian Standards Code AS: 5601
WARNING
WARNING
When using an LPG/Propane supply system in an enclosure,
ventilation must be provided. Gas vapour is highly explosive
and can cause serious bodily injury or damage to property if
allowed to accumulate in a confined space and ignited.
500mm min
230mm min
AGA approved
propane
regulator (not
included)
QCC LPG
Cylinder (not
included)
Stainless steel flex line or AGA
approved hose (not included)
Shut off valve (not included)
AGA approved Natural Gas
regulator
Typical installation drawing
Propane (LPG) Installation
Natural gas installation
20mm min rear
clearance
Installing the Inbuilt Side Burner
This appliance can only be installed in an enclosure
constructed of non combustible material.
1. Determine the position of the cutout for the side
burner using the diagram shown on this page.
2. Ensure that no gas, electricity or any other services
run near the position of the cutout.
3. Depending on the depth of the bench into which the
side burner is being installed, it may be necessary to
connect the gas hoses to the side burner first.
4. Secure the side burner by drilling through the
mounting plate.
360mm
507mm
412mm
45mm
50mm
70mm 70mm
220mm
308mm
168mm 217mm
83mm
508mm
498mm
27mm
220mm
220mm
220mm
220mm
973mm
816mm
854mm
660mm
697mm
495mm
530mm
1011mm
Gas inlet
3/8 SAE
male thread
Gas inlet
3/8 SAE
male thread
Gas inlet
3/8 SAE
male thread
Gas inlet
3/8 SAE
male thread
5 Burner
4 Burner
3 Burner
2 Burner
168mm
168mm
168mm
168mm
13mm
13mm
13mm
13mm
MODEL DIMENSIONS (BUILT-IN) AGA APPROVAL 3986
Model A mm B mm C mm Wt. kg
Signature S3000S 3B 659 223 571 37.0
Signature S3000S 4B 816 223 571 45.5
Signature S3000S 5B 973 223 571 53.0
Signature S3000E 3B 659 223 571 37.0
Signature S3000E 4B 816 223 571 45.5
Signature S3000E 5B 973 223 571 53.0
Balcony 2B 492 223 630 30.0
SIGNATURE S3000 SERIES AND BALCONY
Gas Injector Input/burner Pressure
Size (mm) MJ/Hr KPa
LPG 1.27 19 2.75
Natural gas 2.1 19 1