49-80507-6
15
INSTALLATION BELOW A SINGLE OVEN
INSTALLATION BELOW A DOUBLE OVEN
When installed, the front face of the warming
drawer will be nearly flush with cabinetry doors
or drawer fronts.
Drawer overlaps will conceal cut edges on all
sides of the opening.
The rough opening for the drawer must be:
³'HSWK 231/2” minimum from inside back to
front of cabinet frame.
³:LGWK 251/2” for 27” wide models
281/2” for 30” wide models.
³+HLJKW 91/4”
³ Allow 2” minimum between oven and drawer
cutouts for clearance of overlaps
NOTE: If you are installing in frameless cabinets,
it may be necessary to install 1/2” wide cleats to
accept drawer mounting screws. See drawer to find
exact locations of mounting screws.
When installed under a wall oven:
Warming drawers are suitable for installation below
only certain specified wall oven models. See the
label attached to the top of the warming drawer for
suitable models.
NOTE: Electrical receptacle can be installed as
shown for countertop installations. Do not install
receptacle above the top of the warming drawer
cutout.
PREPARING CABINET: BELOW WALL OVENS
INSTALLATION INSTRUCTIONS
Installation Instructions
23
1
/2
Min.
2x2 or 2x4
anti-tip block
against rear
wall 9” from
floor to bottom
of block
1" Min. above toekick or
adjust to oven installation
height
A
NOTE: Additional clearance between cutouts
may be required. Check to be sure that oven
supports above the warming drawer location
do not obstruct the required interior 23
1
/2
depth and 9
1
/4” height.
2" Min.
Allow 5/8”
overlap on
all sides
10
1
/2
23
1
/4
9"
9
1
/4
B
Oven
cutout
Dimension A Dimension B
27" Drawer 25
1
/2” 26
3
/4
30" Drawer 28
1
/2” 29
3
/4"
IN CANADA, THE WALL OVEN
IS ONLY APPROVED FOR
INSTALLATION WITH A BOTTOM
CUTOUT AT A MINIMUM OF
32.5” FROM THE FLOOR.
CAUTION
NOTE: Additional clearance between cutouts
may be required. Check to be sure that oven
supports above the warming drawer location
do not obstruct the required interior 23
1
/2
depth and 9
1
/4” height.
2" Min
1" Min. above
toekick
2x2 or 2x4 anti-
tip block against
rear wall 9” from
floor to bottom
of block
23
1
/2
Min.
Allow 5/8” overlap
on all sides
A
23
1
/4
10
1
/2
9"
9
1
/4
Oven
cutout
B
IN CANADA, THIS DRAWER IS NOT APPROVED
FOR INSTALLATION UNDER A DOUBLE OVEN.
CAUTION