Rinnai Australia 20 Energysaver® - Operation & Installation Manual
Location
When positioning the heater the main variables governing the location are Flueing and Warm Air
Distribution.
This heater must not be installed where curtains or other combustible materials could come into
contact with it. In some cases curtains may need restraining. Refer to page 2 for additional safety
consideration.
Gas Supply
The gas supply terminates outside the heater at the rear of the appliance.
Locate the gas supply pipe to suit position as per the heater gas inlet. Refer to the drawings on page 18
and page 19 for appliance gas inlet location.
Gap required between the wall and heater body is 85 mm to 200 mm depending on Back Cover set
used.
Purging the gas supply
All foreign materials such as filings must be purged from the gas supply, as they may cause the gas
control valve to malfunction.
Electrical Supply
This heater has a power cord with a three pin plug supplied. The cord passes out of the rear of the
appliance and can extend to the left or right of the appliance.
A dedicated 240 V earthed 10 Amp power point must be used with this appliance. The power point
must to the left or the right side, it must not be above the heater. Alternatively the appliance can be
direct wired if the power supply is to be concealed.
For all installations, ONLY Rinnai Energysaver
®
Flue components MUST be used.
The Rinnai Energysaver
®
MUST NOT be flued into ‘natural draft’ flue system or via
a chimney.
Consult the Rinnai ‘Energysaver
®
Space Heater Co-Axial flue System installation’
manual included with the ‘On Wall’ or ‘Direct’ flue kits for detailed flue installation
instructions.
Gas pipe sizing must consider the gas input to this appliance as well as all other
gas appliances in the premises. The gas meter and regulator must be specified for
the total gas rate. Suitable sizing chart such as the one in AS 5601 should be used.
Consult a qualified electrician if direct wiring is required as it must comply with the
requirements of AS5601 and AS3000 and any other relevant local regulations.
WARNING
WARNING
IMPORTANT
HEATER LOCATION