User Manual BDH4222V/BDH4223V
25
If multiple commands are transmitted, make sure to wait for the
response signals of the monitor before sending the next command.
The following are response command signals:
Command Parameters
These remote control commands are available to send to the monitor
using RS-232.
Response Error
80 70 MODE ERROR
80 71 ITEM ERROR
80 72 FORMAT ERROR
Item Cmd Data Details
Read 80 81-A7 Reads the monitor current
settings for command 81 thru
A7
Volume 81 01-64H Set between 01-64H
Power On/Off 83 00-01 00=Off; 01=On
Brightness 85 01-64H
Contrast 86 01-64H
V-Size 87 01-64H
V-Position 88 01-64H
H-Size 89 01-64H
H-Position 8A 01-64H
Color 8E 01-64H
Tint 8F 01-64H
Sharpness 90 01-64H
Input Select 91 00-07 00=TV; 01=AV1; 02=AV2;
03=AV3; 04=Component 1;
05=Component 2; 06=RGB;
07=DVI
Recall 92 00 00=Initiate recall
Mute On/Off 95 00-01 00=Off; 01=On
PanelKey Lock 96 00-01 00=Off; 01=On
Language 97 00-02 00=English; 01=French;
02=Spanish
Color Temp 98 00-03 00=High; 01=Mid; 02=Low;
03=6500D
Bass 9A 01-64H
Treble 9B 01-64H
Balance 9C 01-64H
Woofer 9D 00-01 00=Off; 01=On
BBE 9E 00-01 00=Off; 01=On
Surround 9F 00-02 00=Off; 01=3D Stereo;
02=3D Mono
RF Input A0 00-01 00=Air; 01=Cable
Full Search A1 00 00=Initiate full search
MTS A4 00-02 00=Stereo; 01=Mono;
02=SAP
Zoom A5 00-05 00=16:9; 01=Panorama;
02=4:3; 03=Zoom1;
04=Zoom2; 05=Zoom3
PIP/POP A7 00-03 00=Normal; 01=PIP;
02=POP1; 03=POP2 (4:3);
04=POP3 (16:9)