Sharp AR-C200P: Maintenance • 347
2. Move the two locking levers (1) to the rear of the machine to
release the fuser unit, then use the handle to remove the fuser
from the printer.
3. Unpack the new fuser unit and lift off the shipping tape at either
end. As you remove the tape, the levers at either end of the fuser
should move into the locked position.
4. Using the handle (2), install the new fuser unit into the printer.
Make sure the two spring loaded locking levers (1) lock the fuser
unit into place.
(1)