OPERATION
MAIN BURNER ADJUSTMENTS:
All Salamanders are provided with a fixed burner orifice to provide 10,500
BTU/HR per burner at the “MAX” setting for NATURAL gas supplied at 5.0”
W/C pressure and 10,500 BTU/HR per burner at the “MAX” setting on
PROPANE gas supplied at 10.0” W/C pressure.
The “LOW” setting is adjustable and should be set as follows:
1. Set the burner valve knob to the low setting and remove the burner knob.
2. Insert a thin bladed screwdriver into the valve stem to engage the slot inside
the stem.
3. Holding the valve stem turn the setscrew clockwise to decrease the rate and
counter clockwise to increase rate.
4. Proper adjustment is attained at a point where the burner flame travels back
and forth across the face of the ceramics. (If set too low a constant spark
will be continuous. If this occurs increase the low setting.)
This adjustment has been factory pre-set, however, with changing pressures this
adjustment may need to be re-done after installation.
THIS IS NOT CONSIDRED A MANUFACTURING DEFECT AND IS
NOT WARRANTABLE
WARNING NEVER cover any slots, holes or passages in the oven bottom or
cover an entire rack with materials such as aluminum foil. Doing so blocks airflow through
the oven and may cause carbon monoxide poisoning. Aluminum foil linings may also trap
heat, causing a fire hazard.