Technical data
Table 2
Conversion with different gas to the regulation gas used in the factory.
Identical operations for both burners:
check the oven is disconnected from the electrical power supply
open the oven door completely
remove the bottom plate from the oven (fig. 4)
remove the burner by unscrewing screw A
remove injector “B” and replace it following the instructions shown in table 2 (check
there are no gas leaks on completing the operation)
reinstall the oven burner
put the plate back in place
FORNO
Ø Gas injector G30/G31 mm 0,73
Ø Gas injector G20/G31 mm 1,15
Ø Gas bypass G30/G31 mm 0,42
CAT. I3,I2, I2L sealed in factory
CAT. II2H3,II23 for gas G30/G31 screwed tight; for gas G20/G25
regulated for 0,72 kW capacity.
Rated capacity in kW 2,4
Minimum capacity in kW 0,72
Rated consumption of G30 in Kg/h 0,175
Rated consumption of G20 in m3/h 0,228
Rated consumption of G25 in m3/h 0,266
Position of ring nut G30/G31 mm 14
Air regulation (“X”) G20/G25 mm 5
Power supply voltage = 220V AC
Installed power = 1,.5kW (oven with electric grill)
Minimum air exchange needed for combustion is 4,8 m
3
/h.
Fig.4
42