Condition/Problem Things to Check Solution
Nodisplay/partialdisplay/
unit will not turn on
Checkelectrical(wall)
outlet
Makesureunitispluggedintoafunctioningwalloutlet.
Checkconnectionatfront
of unit
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
Checkdatacableintegrity Allwiresincableshouldbeintact.Ifanyarevisiblycrimpedor
cut, replace cable.
Checkdatacable
connections/orientation
Besurecableisconnectedsecurelyandorientedproperly.Small
latch on connector should line up and snap into place.
Checkconsoledisplayfor
damage
Checkforvisualsignthatconsoledisplayiscrackedorotherwise
damaged. Replace Console if damaged.
ConsoleDisplay IfConsoleonlyhaspartialdisplayandallconnectionsarefine,
replace the Console.
Iftheabovestepsdonotresolvetheproblem,contactyourlocal
distributor for further assistance.
UnitoperatesbutContact
HRnotdisplayed
HRcableconnectionat
Console
BesurecableisconnectedsecurelytoConsole.
HRcableboxconnection BesurecablesfromhandlebarsandcabletoConsolearesecure
and undamaged.
Sensorgrip BesurehandsarecenteredonHRsensors.Handsmustbekept
stillwithrelativelyequalpressureappliedtoeachside.
Dryorcallousedhands Sensorsmayhavedifficultywithdriedoutorcallousedhands.
Aconductiveelectrodecream(heartratecream)canhelpmake
better conduct. These are available on the web or at medical or
some larger fitness stores.
StaticHandlebar Iftestsrevealnootherissues,StaticHandlebarshouldbere-
placed.
UnitoperatesbutTelemet-
ricHRnotdisplayed
ChestStrap(optional) Strapshouldbe“POLAR
®
”compatibleanduncoded.Makesure
strapisdirectlyagainstskinandcontactareaiswet.
Interference Trymovingunitawayfromsourcesofinterference(TV,Micro-
wave,etc).
ReplaceChestStrap IfinterferenceiseliminatedandHRdoesnotfunction,replace
strap.
Replace Console IfHRstilldoesnotfunction,contactyourlocaldistributorfor
further assistance.
UnitoperatesbutTelemet-
ricHRdisplayedincorrectly
Interference MakesurethattheHRreceiverisnotblockedbyapersonal
electronic device in the left side of the media tray.
Consoledisplays“E2”error
code
Checkdatacableintegrity Allwiresincableshouldbeintact.Ifanyarecutorcrimped,
replace cable.
Checkdatacable
connections/orientation
Besurecableisconnectedsecurelyandorientedproperly.Small
latch on connector should line up and snap into place.
ConsoleElectronics Iftestsrevealnootherissues,contactyourlocaldistributorfor
further assistance..