Below is a description of the features in this menu:
No.: Provides the order in which the IVS rules will be displayed in the menu.
Name: Allows the user to customize a name for their rule. Double click the name in the Rule column to modify.
Schedule: Allows the user to set a schedule in which the IVS rule will be triggered. A Schedule must be set for IVS
rules to function.
Duration: Allows the user to set a specific time before the abandoned object triggers an event. The default is 10
seconds however it can be modified up to 3600 seconds.
Record: This checkbox allows the user to enable the camera to record video when an IVS event is triggered.
Record Delay: This field specifies, in seconds, how long the delay between IVS events should be. The default is 10
seconds however this can be modified between 10~300 seconds.
Send Email: This checkbox allows the user to enable the camera to send an email when an IVS event is triggered.
Snapshot: This checkbox allows a snapshot of the IVS event to be sent via Email when triggered.
Draw Rule: This option allows the user to use their mouse to customize (draw) a rule/area on the live monitoring
screen. This will be the area or line in which an IVS rule will be triggered.
Clear: This option is used to clear the drawn rule set on the live monitor screen.
Target filter: Sets a maximum and minimum pixel size in which an event will be triggered.
Draw Target: Allows the user to set a target area on the live monitor screen. An IVS event will not occur outside
the target box.
Clear: Clears the modified target area to draw the target area on the live monitoring screen.
Pixel Counter: Used to measure and set the number of pixels in the target area on the live monitoring screen.
To reset to default settings, click the Reset Defaults button. To refresh the page, click the Refresh button. To save
the settings, click the Save button.
Setting an Abandoned Object Rule
1. Select Abandoned Object from the Rule Type menu. Set a name for the rule by double clicking the mouse over
the Name of the rule.
2. Click on Setup to set a schedule, set your periods (if any) and click Save to continue.
3. In the Duration menu, type in the number of seconds you would like to have before an abandoned object
triggers an event. For best results, it is recommended to keep this option as default (10 seconds).
4. Enable the Record checkbox to record the event.
5. Enable the Send Email and Snapshot checkboxes if you would like a snapshot of the event emailed to you. A
valid Email address must be established in the camera prior to enabling this setting.
6. Click the Draw Rule option and right click on the live monitoring screen. Use the mouse to draw your initial line.
Once the initial line is set, right click the mouse again to continue drawing the region. Repeat the process and left
click the mouse to complete the region. Right click on the live monitoring screen when finished to set the rule.