US Stove Company 5501S Stove

User Manual - Page 4

For 5501S.

PDF File Manual, 56 pages, Read Online | Download pdf file

5501S photo
Loading ...
Loading ...
Loading ...
4
INSTALLATION OPTIONS
Read this entire manual before you install and use your
pellet stove. Failure to follow instructions may result in
property damage, bodily injury, or even death!
(See specic installation details for clearances and other
installation requirements)
A Freestanding Unit—supported by pedestal/legs and
placed on a non-combustible oor surface in compliance
with clearance requirements for a freestanding stove
installation.
Your pellet stove may be installed to code in either a
conventional or mobile home (see SPECIAL MOBILE HOME
REQUIREMENTS). The installation must comply with the
Manufactured Home and Safety Standard (HUD), CFR3280,
Part 24.
It is recommended that only a authorized technician install
your pellet stove, preferably an NFI certied specialist.
DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM.
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty.
IMPROPER INSTALLATION: The manufacturer will not be held
responsible for damage caused by the malfunction of a
stove due to improper venting or installation. Call (800) 750-
2723 and/or consult a professional installer if you have any
questions.
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please adhere
to the installation clearances and restrictions. Any reduction
in clearance to combustibles may only be done by means
approved by a regulatory authority.
FLOOR PROTECTION
This heater must have a non-combustible oor protector
(UL1618 ember protection) installed beneath it if the oor is
of combustible material. US: Floor protector should be UL
listed or equal too, needs to extend 6” to the front, 6” to
each side, 1” to the rear of the unit. Under and 2” beyond
each side of the cleanout tee if an interior vertical instillation.
Canada: Floor protector should comply with CAN/
ULC standards. Needs to extend 18” to the front, 8” beyond
each side of the unit.
C
B
A
E
F
D
J
I
G
H
ADJACENT WALL
ADJACENT WALL
Installation
CLEARANCES
A Side Wall to Stove 10 in (254 mm)
B Side Wall to Vent Pipe 11.5 in (292 mm)
C Back Wall to Stove 11.875 in (302 mm)
D Back Wall to Vent Pipe 3 in (76 mm)
E Ceiling to Floor 84 in (2134 mm)
F Ceiling to Stove 53.875 in (1434 mm)
CORNER CLEARANCES
G Side Wall to Stove 7.5 in (191 mm)
H Side Wall to Vent Pipe 11.25 in (286 mm)
I Back Wall to Stove 7.5 in (191 mm)
J Back Wall to Vent Pipe 3 in (76 mm)
K
N
L
L
O
P
M
K
N
L
L
O
P
M
FLOOR PROTECTOR CLEARANCES
K Back to Stove
U.S. 1 in (26 mm)
Canada 8 in (204 mm)
L Side to Stove
U.S. 6 in (153 mm)
Canada 8 in (204mm)
M Front to Stove
U.S. 6 in (153 mm)
Canada 8 in (204 mm)
N Back to Flue 2 in (51 mm)
O Overall Length 31 in (788 mm)
P Overall Width 38 in (966 mm)
THROUGH THE WALL
INSTALLATION
INTERIOR VERTICAL
INSTALLATION