13
WARNING: FAILURE TO PROPERLY MAINTENANCE THE CLEAN OUTS
WILL RESULT IN POOR PERFORMANCE OF THIS STOVE.
INTERIOR CHAMBERS
Burn Pot: Periodically remove and clean the burn pot and the area inside the burn pot housing. In particular, it is
advisable to clean out the holes in the burn pot to remove any build up that may prevent air from moving through
the burn pot freely.
Heat Exchanger: There is a clean out plate on both sides of the heat exchanger that need to be removed to clean
y ash out of the heat exchanger. The cleanouts are located inside the cabinet doors, on the lower front corners of
the heat exchanger. To access these clean outs, you must remove both side panels. The clean outs are secured
to the rebox with (2) 5/16” screws. Remove the clean outs and vacuum out any accumulated ash. This should be
done at least once per month or more frequently if large amounts of ash are noticed while cleaning or if the stove
does not seem to be burning properly.
If a vacuum is used to clean your stove, we suggest using a vacuum designed for ash removal. Some regular vacuum
cleaner (i.e. shop vacs) may leak ash into the room.