Filter maintenance
Warning: If the HydroTap
®
G4
is switched off for a long period
of time (e.g. more than a
weekend), run water through
the AMBIENT water outlet
for at least 5 minutes before
consumption.
Caution
. A small amount of water will drip as the cartridge is
removed.
Do not tilt the cartridge as water may spill from it if tilted.
Unpack replacement cartridge and remove sanitary cap, write today’s
date where shown on the label.
Avoid touching the filter o-rings and filter opening as this may cause
bacterial contamination of the cartridge.
Moisten the o-rings with water, align the front cartridge label to the
left (as shown in the “insert filter” diagram below), and push the new
cartridge up into the filter head.
Turn the cartridge a quarter turn anticlockwise until the cartridge comes
to complete stop and is locked into position, with the front label facing
forward.
Initiate the filter flush programme by scrolling through the menu screen
(see page 13).
When completed, wipe up any spills and dispose of spent filter cartridge
and packaging thoughtfully.
Close the door to secure the appliance.
Adjust the filter settings in Section G (see page 18) litres and days.