802258UK G4 Boiling (& ambient) residential, user guide - August 2015 - V2.01 Page 23 of 24
Filter maintenance
Warning: If the HydroTap
®
G4
is switched off for a long period
of time (e.g. more than a
weekend), run water through
the AMBIENT water outlet
for at least 5 minutes before
consumption.
•
Caution
. A small amount of water will drip as the cartridge is
removed.
• Do not tilt the cartridge as water may spill from it if tilted.
• Unpack replacement cartridge and remove sanitary cap, write today’s
date where shown on the label.
• Avoid touching the filter o-rings and filter opening as this may cause
bacterial contamination of the cartridge.
• Moisten the o-rings with water, align the front cartridge label to the
left (as shown in the “insert filter” diagram below), and push the new
cartridge up into the filter head.
• Turn the cartridge a quarter turn anticlockwise until the cartridge comes
to complete stop and is locked into position, with the front label facing
forward.
• Initiate the filter flush programme by scrolling through the menu screen
(see page 13).
• When completed, wipe up any spills and dispose of spent filter cartridge
and packaging thoughtfully.
• Close the door to secure the appliance.
• Adjust the filter settings in Section G (see page 18) litres and days.