Firman WH03342 Electric Start RV Ready 4125-Watt Dual Fuel Inverter Generator

Product's Documents

Below are documents related to this product, you can read online or download:
WH03342 photo

Operating Manual

This is the main product document for model WH03342.

The file format is pdf, 49 pages, you can download this manual here .

background
OPERATOR'S
MANUAL
DUAL FUEL INVERTER GENERATOR
lntertek
IIOl1141
MODEL
NUMBER
WH03342
R
ev
Level :00
Record
product
information
to
reference
when
ordering
parts
or
obtaining
warranty
coverage.
DO
NOi'
AEl\lAN
lOSTOAEIJ
CAU.ua,-
1-844-347--62&1
Ai
~
FOR QUESTIONS
OR
SERVICE INFORMATION
S&RIAL
NUM&R:
PURCHASE
DATE:
____
_
P/ N ,
333748301
Rev,00
background
Supplier's
Declaration
of
Conformity
47
CFR
I
2.1077
Compliance
Information
FIRMAN
WH03342
INVERTER
GENERATOR
Firman
Power
Equipment
8644
W.
Ludlow
Dr.
Suite
#6
Peoria,
AZ
85381
Telephone:
l-844-347-6261
www.firmanpowerequipment.com
FCC/IC
Compliance
Statement
1.
This
dev
i
ce
complies
w i
th
Part
15
of
the
FCC Ru les.
Operat
i
on
is
subject
to
the
follow
i
ng
two
condit
i
ons:
la.
This
device
may
not
cause
harmful
interference
.
lb.
This
device
must
accept
any
interference
received,
including
interference
that
may
cause
undes
i
red
operation
.
2.
Changes
or
modificat
i
ons
not
expressly
approved
by
the
party
respons
i
ble
for
com
plia
nee
could
void
the
user's
authority
to
operate
the
equipment
.
NOTE:
The
FIRMAN
WH03342
inverter
generator
has
been
tested
and
found
to
comply
with
the
limits
for
a
Class
B
digital
device
,
pursuant
to
part
15
of
the
FCC
Rules.
These
limits
are
designed
to
provide
reasonable
protection
against
harmful
i
nterference
in a
res
i
dent
ial i
nstallation.
This
equ
i
pment
generates,
uses
and
can
radiate
radio
frequency
energy
and,
if
not
i
nstalled
and
used
in
acco
r
dance
with
the
instructions,
may
cause
harmful
interference
to
rad
io
communicat
i
ons
.
However,
there
is
no
guarantee
that
interference
will
not
occur
in
a
pa
rticu
la r
installation.
If
this
equipment
does
cause
harmful
interference
to
radio
or
television
reception,
which
can
be
determined
by
turning
the
equipment
off
and
on,
the
user
is
encouraged
to
try
to
correct
the
interference
by
one
o r
more
of
the
follow
i
ng
measures:
Reorient
or
relocate
the
receiving
antenna
.
Increase
the
separation
between
the
equipment
and
receiver.
Connect
the
equ
i
pment
into
an
out
l
et
on
a c i
rcuit
different
from
that
to
which
the
receiver
is
connected
.
Consult
the
dealer
or
an
experienced
radio/TV
technician
for
help.
Changes
or
modificat
i
ons
to
equipment
not
expressly
approved
by
FIRMAN
could
void
the
user's
authority
to
operate
the
equipment.
background
INTRODUCTION
Table
of
Contents
Introduction
............................................................
.
.......
.
01
Features
and
Controls
..........................................................
05
Operation
..........................................
.
................
.
...........
11
Maintenance-
Storage
..........................................................
27
Troubleshooting-
Specifications
......................
.
.....
.
...................
35
Parts
Diagrams
-
Parts
Lists
-Wiring
Diagram
....................................
37
Service
-
Warranty
...............................................................
43
( REGISTER
YOUR
PRODUCT
J
Register
your
product
using
the
QR
code
provided
or
at
www.firmanpowerequipment.com.
INTRODUCTION
Thank
you
for
purchasing
a
FIRMAN
generator.
You
have
selected
a
high-quality
,
precision
engineered
generator
set
designed
and
tested
to
give
you
years
of
satisfactory
service.
This
generator
is
Dual
Fuel
and
capable
of
running
on
gasoline
and
liquid
petroleum
gas
(LPG). This
generator
is
not
intended
to
be
run
unattended
or
to
supply
powe
r
to
life
safety
support.
This
manual
contains
safety
information
to
make
you
aware
of
the
hazard
s
and
risks
associated
with
generator
products
and
how
to
avoid
them.
This
generator
is
designed
and
intended
only
for
supplying
electrical
power
for
operating
compatible
electrical
lighting,
appliances,
tools
and
motor
loads,
and
is
not
intended
for
any
other
purpose
.
It
is
important
that
you
read
and
understand
these
instructions
thoroughly
before
attempting
to
start
o r
operate
this
inverter
generator.
Save
these
original
instructions
for
future
reference.
All
info
r
mation
in
this
publication
is
based
on
the
latest
production
information
available
at
the
t i
me
of
ap
prov
a I
for
printing.
The
manufacturer
reserves
the
rig
ht
to
change,
alter
or
otherwise
imp
rove
the
generator
and
this
documentation
at
any
time
without
prior
notice.
Engli
sh
01
Customer Service: 1-844-FIRMAN1
background
INTRODUCTION
Indicates
a
hazard
which,
if
not
avoided,
will
result
in
death
or
serious
injury.
Indicates
a
hazard
which,
if
not
avoided,
could
result
in
death
or
serious
injury.
Indicates
a
hazard
which,
if
not
avoided,
could
result
in
minor
or
moderate
injury.
Indicates
information
considered
Important,
but
not
hazard-related
&
Safety
Ale,t
Symbol
-
Ind
iea
tes
,
pole
n
ti,
I pees
on,
I i nj
u,y
hawd.
~
Operator
's
Manual-
Failure
to
follow
warnings.
instructions
and
operator
's
manua
I
could
result
in
death
or
serious
injury.
&
Toxic
Fumes-
Engine
exhaust
contains
carbon
monoxide,
a
poisono~s
gas
that
will
kill
you
in
minutes.
You
cannot
smell
1t
or
see
1t.
&
~':merator
could
cause
electrical
shock
resulting
in
death
or
serious
inJury.
£
Fire-
Fuel
and
its
vapors
are
extremely
flammable
which
could
cause
burns
or
fire
resulting
in
death
or
serious
injury.Engine
exhaust
could
cause
fire
resulting
in
death
or
serious
injury.
~
Hot
Surface-
Muffler
could
cause
burns
resulting
in
serious
injury.
English 02 Customer Service: 1 ·844·FIRMAN 1
background
INTRODUCTION
&
WARNING!
This
product
can
expose
you
to
chemicals
including
gasoline
engine
exhaust,
which
is
known
to
the
State
of
California
to
cause
cancer,
and
carbon
monoxide,
which
is
known
to
the
State
of
California
to
cause
birth
defects
or
other
reproductive
harm.
For
more
information
go
to
www.P65Warnings.ca.gov.
This
outdoor
generator
can
be
used
to
power
outdoor
items
using
extension
cords
.
NOTICE
If
you
have
questions
about
intended
use,
contact
FIRMAN
customer
service.
This
inverter
generator
is
designed
to
be
used
only
with
FIRMAN
authorized
parts.
System
Ground
The
generator
neutral
is
floating,
which
means
that
the
AC
stator
winding
is
isolated
from
the
grounding
fastener
and
the
AC
receptacle
ground
pins.
On
a
floating
neutral
generator
the
AC
receptacle
ground
pins
are
not
functional.
Electrical
devices,
such
as
a
ground
fault
circuit
interrupter
(GFCI),
requiring
a
functioning
AC
receptacle
ground
pin
will
not
operate.
Compliance
Requirements
There
may
be
Federal
or
State
regulations,
local
codes,
or
ordinances
that
apply
to
the
intended
use
of
the
generator.
Consu
It
a
qualified
electrician,
electrica
Ii
nspector,
or
the
local
agency
having
jurisdiction.
This
generator
is
not
intended
to
be
used
at
a
construction
site
or
similar
activity
as
defined
by
N FPA
70-2020
(NEC)
section
590.6.
To
Restore
Power
Using
Extension
Cords
English 03
120V
OUTLET
Customer
Service 1-844-FIRMAN1
background
INTRODUCTION
1.
0
nly
use
grounded
cords
marked
for
outdoor
use
rated
for
your
loads.
©
~
To
provide
power
using
extension
cords
0
I
Total
Minimum
Cauge,
Outdoor
Rated
Amperage
Up
to
SO
FT (1Sm)
Up
to13A
CD
Up
to
15A
e
Up
to
20A
Up
to
30A
2.
Follow
cord
safety
instructions.
3.
Install
carbon
monoxide
alarm(s)
.
4.
When
operating
portable
generator
with
extension
cords,
make
sure
portable
generator
is
located
downwind
in
an
open,
outdoor
area,
at
least
20
ft.
(6
m.)
from
occupied
spaces
w i
th
exhaust
pointed
away.
5.
Extension
cords
running
directly
into
your
home
,
powering
indoor
it
ems
IS
NOT
RECOMMENDED.
&
DANGER!
Engine
exhaust
contains
carbon
monoxide,
a
poisonous
gas
that
will
kill
you
in
m i
nutes.
You
cannot
smell
it,
see
it,
or
tas
t e
it.
Even
if
you
do
not
smell
exhaust
fumes,
you
cou
ld
still
be
exposed
to
carbon
monoxide
gas.
e
Extension
cords
runn
i
ng
direct
ly in
to
the
home
incre
a
se
your
ri
sk
of
carbon
monoxide
poison
i
ng
through
any
openings.
e
If
an
extension
cord
running
directly
into
your
home
is
used
to
power
indoor
items,
the
operator
recognizes
that
this
increases
the
risk
of
CO
poisoning
to
peop
le
inside
the
home
and
assumes
that
risk.
Eng
li
sh 04 Custom
er
Service: 1-844-FIRMAN 1
background
FEATURES
AND
CONTROLS
1-
Fixed Carrying
Handle
2-1.8
Gallon(6.8L)
Capacity
Fuel
Tank
3-
LPG
Hose
Quick
Connect
Inlet
4-
Recoil
Starter
5-
Never
Flat
Wheel
6-
Control
Panel
7-
Muffler/SparkArrester
8-
Folding
Handle
9-
Maintenance
Cover-Oil
filler
and
air filter access.
10-
LPG
Hose
with
Regulator
11-
Spring
Clamp
to
Hang
Regulator
on
Handle
12-
Data
Decal/
Serial
Number
•we
are
always
working
to
improve
our
products.
Therefore,
the
enclosed
product
may
differ
slightly
from
the
image
on
this
page.
English 05 Custo
me
r Service 1-844-FIRMA
N1
background
FEATURES
AND
CONTROLS
English 06
Customer
Service 1-844-FIRMAN1
background
FEATURES
AND
CONTROLS
CD
A DANCER A PELICRO A DANCER
Uaing a generator indoora
CAN
Kill
Ublzllr
un
90norador
Oii
lntAl~o"'
PUEDE
PIIOYOCARIA
IIIUEIITE
EN
CUESTI6N
DE
MINUTOS.
L.m
-do!
UtiliH<
un
g..,_url
lfnbllriour
PE\JTVOUS
TUER
'l'OU
IN
MINUTES. C.onorotor
exhaust
EN
QUELQUES
MINUTES.
LAI
g
■z
,f~mon\
du
cont.In•
c:11rbon
monoxide,
gonor,dor
conlianon
-do
do
carbono,
II
aiol 9"1hteur
conUennent
du
moncayde
de
c,rt,orw,.
This
is a
poison
JCH.1
cannot••
or smell.
una
1U1tand1
YlnlflOSI
ciu,
no
puede
wr..
nl
olane.
Cid
at...,
poison
qu•
vou1
n•
pouvez.
ni
voir
ni
11ntir.
fl
...
~~
fl
...
Ji)IHj
fl
.
..
lit~
NEVER
UIO ln.sldn
homo
Only
UN
OUTSIDE
ond
No
utll1ce
NUNCA al
g-,.
utilic:e-AI.AIRE
LIBRE
NE
JAMA
IS
utilbier
d1n1
.l.n'IIHll18rqlfi
endor
en
el
lntMfor
de
su
y
1..,.
do
van\onas,
un
911,ag
ou
.6
Mnblriaur.
CEXT~RIEUR
o\.
distance
«
gararg-.
EVEN
IF
doors
rar
away
fram
windows.
=rE~.n!~c~~
puert:.11
y
orlftcloa
de
lil~ME
avac
In
portao
o\
do
toutM
Ion-
portao
ond
wlndowuro
opon.
doon,and
Wntl.
ywntan
■s
blartas.
vantilaclcin.
...-.
...
-
et
ouvertutM.
English
£
~~
Fuel
IMI
lndlcatDr
lndlcador
de
nlvel
de
combusllble
lndlcablurde
nlveeu
decarburant
Fuel
is
fllmmable
whicll
could
cause
~~':,
~~~~:,,9:1~
o~:~°':
:!\~·
miml1es
bofor1
refueling.
Do
not
flll
fuel
above
fuel
I...i
Indicator.
Never
add
fuel
1D
a
hot
or
running
genelllDr.
El
cDmbusllblo
es
lnflamable,
lo
quo
podrfa
causar
quamaduras
rasultantes
an
la
muarta
o
lesiDnes
graws.
Apague
el
motor
y
dijelD
onfl1ar
al
menDS
2
minutes
antes
do
racargu
combustible.
0
No
Ilene
el
combustible
por
encima
del
indicador
de
nivel.
0
No
cargue
nunca
combustible
en
un
generadDr
callente
o
en
fundonamlentD.
Le
carburant
est
inflammable,
ca
qui
peut
p11M1quer
des
br1llur1S
entnrnant
Ill
mort
DU
des
blessures
graws.
0
£telndre
le
moteur
et
le
lllsser
re1roldlr
au
mDlns
2
mlnutee
avant
le
rampllasage.
Ne
ll8S
ramplir
111-d
...
de
l'indicablur
de
niveau
maximal
da
carburant.
Na
jamais
ajoutar
de
carburant
I
une
g~n6ratrlce
chaude
DU
en
man:he.
®
AU1'mulllC
SNlffllFF
!VU
MUST:
MIMlD
lllESHAIRAND
GET
MBllCAI.
HELP
IFSICIC,
DIZZY
CR
WEAK
1,......,..,
.....
A
WARNINC::Thil product
and
the
engine exhauat
from
this
product can expo••
you
to
chemical• lncludlng
co, whlch are known
to
the
Stata
of
CaHfornla
ta
cause
cancer
or
caun
birth defects
and
other reproductive harm.
For
more
Information,
go
to
ltlDMM'2!iSWarnio111aamr.
................
A
ADVERTENCIA:
Eate
productoyel
escapedel
motor
de
•te
producto pueden
exponerlo a productosqurmlcos,
lncluldoCO,
qua
en
el
estadode
caurarnla son conocldos
por
cautar cfincer o causardefectos
de
naclmlento u otros dal\oa
reproductivo
.
Par
obt.ner
mlli1
informaci6n,
vay
l80lllllll!
1!&5Wlmiaga.ca.al:lli!
1'11111.IB
.....
IIEIACII.IIIIE
A
AVERTISSEMENT,Ce
produltet
1'4chappemantdu
motaurdece
prod
ult
peuvent
vous exposer
.ti
des
:U~~:~~~~~~!~~~~:li:!r:~~.:~o~•
pour causer
lecanc
rou
cauaer
d■
1
malformation
cong6nitale1
et
autre1
probl6me,de reproduetion. Pour
plu•
d'informations. visitez
»aM!
e&5:w.iltll[DlilS.'a.slelll!
~
CIIIIIEAUIIIMA1111HBE
~
Aab
Alll1IIIAJ1IIIE -
\fil\
IIEAUDII
UI
SlllUBIII:
\fil\
llllUS
DE111Z:
MUE.VA
B.
GENE
RAD
OR
A
UNMEUIIIERTA
AL
IIIRE
LIBRE.
N'UN!'E
B.
ESC.IPE
LfJOS
DE
~~=w~~=-
l'INTILE
ulSINSTAIACIOt.ES~Y
~CU~~~~~
\IOL'IEH
A
UBIIILESE
EN
UN
UJGAA
OONDE
CORRA
IIIRE
F1lESCO
Y
BISIIJE
AVUDA
111:DICASI
SE
SENTJ;
MAI..
M!REAOO
O
ci:a1L
07
All.EZA~/JRAWS
EIOBTEl£Z
DE
~AIDE
111:DICIII..E
EN
CM
DE
MALllll~
D'£T01.1llllSSEMENT
OU
DE
FMUSSE
Customer Service 1-844-FIRMA
N1
background
@
{J)
English
FEATURES
AND
CONTROLS
Point
engine
exhaust
away
from
all
occupied
structures.
Mantenga
los
gases
de
escape
del
motor
leios
de
instalaciones
ocupadas.
Pointer
1'6chappemenl
du
moteur
loin
de
toutes
les
structures
occup6es.
,
NOTICE
AV/SO
AVIS
To
prevent
engine
Para
evitar
danos
en
Pou
r
eviter
d'endommager
damage
the
spark
l
el
mo~or,
el
supresorl
le
moteur,
le
pare-etincelles
arrester
should
be
~e
c~1spas
debe
doit
etre
nettoye
toutes
l
es
cleaned
every
100
hmp1arse
cada
100
hours.
See
horas.
Consulte
el
100
heures.
Consulter
le
Operator's
manual.
manual
del
operador.
manuel
d'utilisation.
...
.:==::.::r
..
"9ct
-.
11.1w1t11111'1CIIMlldOl'lll~eh
08 Custo
mer
Service 1-844-FIRMA
N1
background
FEATURES
AND
CONTROLS
Control
Panel
e--11---------'l
NOTICE
Total
power
drawn
from
all
receptacles
must
not
exceed
the
data
decal
rating.
1.
Engine Start Switch - To
start
engine,
press
and
hold
the
switch
in
the
START
(11)
position,
the
engine
will
crank
and
attempt
to
start.
When
the
engine
starts, release
the
switch
to
the
RUN (I)
position.
2.
Economy
Control
Switch
-
The
Economy
Control
switch
can
be
activated
in
order
to
minimize
fuel
consumption
and
noise
while
operating
the
unit
during
times
of
reduced
electrical
output,
allowing
the
engine
speed
to
idle
during
periods
of
non-use.
The
engine
speed
returns
to
normal
when
an
electrical
load
is
connected.
When
the
economy
switch
is
off,
the
engine
runs
at
normal
speed
continuously.
3.
3-1
Data-Minder
(Multi-Meter)
- Push
the
SELECT
button
to
show
the
Voltage,
Hertz
and
running
hours.
4.
120V,
20A
Duplex
-
NEMA
5-20R
(Not
GFCI
protected)
A
maximum
of
20
Amps
current
may
be
drawn
from
this
duplex
receptacle.
5.
120V,
30A
RV -
NEMA
TT-30R
A
maximum
of
27.5
Amps
current
may
bed
rawn
from
this
receptacle.
6.
Output
Ready
Indicator
Light
-
Remains
"ON"
during
normal
operating
conditions.
Shuts
"OFF"
when
generator
is
overloaded.
The
green
AC
Power
Indicator
Light
comes
on
when
the
engine
starts
and
generates
power.
7.
Overload
Indicator
Light
-
This
light
turns
"ON"
when
the
generator
is
overloaded
and
will
cut
power
to
the
receptacles.
If
the
engine
overload
indicator
light
comes
on,
the
generator's
wattage/
amperage
capacity
has
been
exceeded
by
connected
electrical
devices
or
by
a
power
surge.
When
this
occurs,
the
green
AC
Power
Indicator
Light
will
go
off.
The
engine
will
continue
to
run,
but
the
red
Engine
Overload
Indicator
Light
will
stay
on
and
power
will
no
longer
be
supplied
to
connected
electronic
devices.
8.
Oil
Warning
Indicator
Light-
Check
oil
level
when
this
light
turns
"ON".
Engine
will
not
run
when
indicator
is
lit.
When
the
oil
falls
below
the
minimum
level,
the
oil
warning
indicator
light
comes
on
and
the
engine
stops
automatically.
The
engine
will
not
start
until
the
proper
amount
of
oil
is
in
the
crank
case.
English
09
Customer
Service 1-844-FIRMAN1
background
FEATURES
AND
CONTROLS
9.
Battery
Power
Restore
Switch
10. DC
SV
2.1A USB
Outlet
11.
Circuit
Breakers
-
The
receptacles
are
protected
by
AC
circuit
protectors.
If
the
generator
is
overloaded
or
an
extern
a I
short
circuit
occurs,
a
circuit
protector
may
trip.
If
trip
ping
occurs,
disconnect
all
electrical
loads
and
determine
the
cause
before
attempting
to
continue
using
the
generator.
Reset
any
tripped
circuit
protectors.
If
multiple
receptacles
are
used
at
the
same
time,
the
total
current
must
be
kept
with-in
the
portable
generator
data
decal
rating.
12. 12V DC
Battery
Charger
Port
-
Plug
the
120
Volt
AC
charger
into
this
port
to
charge
the
generator
battery.
13.
DC Circuit
Breaker-
The DC
receptacles
are
protected
by
an
DC
circuit
protector.
If
the
DC
output
is
overloaded
or
an
external
short
circuit
occurs
the
circuit
protector
will
trip.
14.
Parallel
Operation
Outlets
-These
outlets
are
used
for
connecting
two
FIRMAN
inverter
generators
for
parallel
operation.
A
FIRMAN
parallel
kit(optional
equipment)
is
required
for
parallel
operation.
15.
DC 12V
Output
- 8.3
Amps
of
DC
current
may
be
drawn
from
this
receptacle.
Use
this
outlet
to
charge
12V
automotive
type
batteries
ONLY. See 12V DC
outlet
(Battery
Charger)
section.
16.
Ground
Terminal
-
Consult
an
electrician
or
authority
having
jurisdiction
for
local
grounding
requirements.
17.
Outlet
Cover -
Protect
the
receptacles
from
dust
and
debris.
18. Recoil
Starter
19. LPC
Hose
Connector
(Inlet:
3/8"
Flare
Male)
-
Used
to
connect
LPG
hose
to
generator.
20.
Fuel
Selector
Switch
-
Use
to
select
and
turn
on
gasoline
or
LPG
fuel
source.
Fuel
(gasoline)
valve
is
closed
when
the
switch
is
on
"OFF"
or
"LPG"
positions.
Engine
switch
is
on
when
the
switch
is
on
"GAS"
or
"LPG"
positions.
21.
Choke
Knob -
Used
to
start
a
cold
engine.
22.
LPC
Regulator
Solenoid
Port
23. CO Alert™ Carbon Monoxide (CO) Shutdown Indicator Light -
Indicates
the
engine
shutdown
due
to
carbon
monoxide
accumulation
around
the
generator
or
a CO
Alert
system
fault
occurred.
English
10
Customer
Service 1-844-FIRMAN1
background
OPERATION
l.Location
&
DANGER!
Engine
exhaust
contains
carbon
monoxide,
a
poisonous
gas
that
could
kill
you
in
minutes.
You
CANNOT
smell
it,
see
it,
or
taste
it.
Even
if
you
do
not
smell
exhaust
fumes,
you
could
still
be
exposed
to
carbon
monoxide
gas.
e
Operate
portable
generator
only
outdoors
and
downwind
at
least
20
ft.(6
m)
from
occupied
spaces
with
exhaust
pointed
away
to
reduce
the
risk
of
carbon
monoxide
accumulating.
e
Install
battery-operated
carbon
monoxide
alarms
or
plug-in
carbon
monoxide
alarms
with
battery
back-up
according
to
the
manufacturer's
instructions.
Smoke
alarms
cannot
detect
carbon
monoxide
gas.
e
Do
not
run
this
portable
generator
inside
homes,
garages,
basements,
crawlspaces,
sheds,
or
other
partially-enclosed
spaces
even
if
using
fans
or
opening
doors
and
windows
for
ventilation.
Carbon
monoxide
can
quickly
build
up
in
these
spaces
and
can
linger
for
hours,
even
after
this
product
has
shut
off.
e
If
you
start
to
feel
sick,
dizzy,
weak
or
your
home·s
carbon
monoxide
alarm
sounds,
get
to
fresh
air
right
away.
Call
emergency
services.
You
may
have
carbon
monoxide
poisoning.
Carbon
Monoxide
Alarm(s)
Install
carbon
monoxide
alarms
inside
your
home.
Without
working
carbon
monoxide
alarms,
you
will
not
realize
you
are
getting
sick
and
dying
from
carbon
monoxide
poisoning.
Prevent
Carbon
Monoxide
(CO)
Poisoning
Use
outdoors
and
downwind
at
least
20
ft.
(6
m)
from
any
home.
Point
exhaust
away
from
all
homes
and
occupied
spaces.
Install
CO
alarms
inside
your
home.
To
bettereducateyourselfaboutall
carbon
monoxide
risks,
go
to
www.takeyourgeneratoroutside.com.
English
11
Customer
Service 1-844-FIRMAN1
background
OPERATION
Reduce
Risk
of
Fire
h..
WARN
INC!
Exhaust
heat/gases
could
ignite
combustibles,
structures
or
damage
fuel
~
tank
causing
a
fire,
resulting
in
death
or
serious
injury.
e
Keep
portable
generator
at
least
5
ft.
(l.Sm)
from
any
structure,
trees
or
vegetation
over
12
in
.
(30
cm)
in
height.
e
Select
an
outdoor
site
that
is
dry
and
protected
from
the
weather.
Do
not
move
portable
generator
indoors
to
protect
it
from
the
weather.
e
Do
not
locate
the
portable
generator
under
ad
eek
or
other
similar
structure
that
may
confine
heat
and
airflow.
English
\
,
"
..,,
~
5
fl
.
(1
.5 m)
min
.
/
.1.5m}-~
min
.
~-----
12
I
,\cf
·"'
\
..
,,.,_.
..
I
~
''t
t '
~
20
ft.(6
m)
min
.
Customer Service: 1-844-FIRMAN 1
background
OPERATION
2.
Oil
and
Gasoline/LPG
Add
Engine
Oil
We
recommend
using
SAE
lOW
-
30
API
SL
or
higher
oil
for
best
performance.
Do
not
use
special
additives.
Ambient
temperature
determines
the
proper
oil
viscosity
for
the
engine.
Use
the
cha
rt
to
select
the
proper
oil
for
the
outdoor
temperature
range
expected.
NOTICE
Do
not
attempt
to
crank
or
start
the
engine
before
it
has
been
properly
filled
with
the
recommended
type
and
amount
of
oil.
Damage
due
to
operation
with
no
oil
will
void
your
warranty.
Deg
r
ees
Cels
1
us
0
(0
ut
s1
de)
-6.7
I
20
4.4
15.6 26.7 37.8 48.9
I I I I I
I I
100 120
D
eg
1ees
ra
h
re
nh
c1t
0
(0
uts1de)
I.Place
generator
on
a
flat,
level
surface.
2.Loosen
the
cover
screw
and
remove
the
maintenance
cover.
3.Clean
area
around
oil
fill
and
remove
yellow
oil
fill
cap/dipstick.
4.Wipe
dipstick
clean.
~,~(H
}
~I~
LOMll,_,.(L}
Eng
li
sh
13
Customer Servi
ce
: 1-844-FIRMAN 1
background
OPERATION
5.
Using
oil
funnel,
slowly
pour
contents
of
provided
oil
bottle
into
oil
fill
opening
until
oil
reaches
upper
limit
"H"
mark
on
the
dipstick.
Be
careful
not
to
overfill.
Overfilling
could
cause
engine
starting
problems
or
engine
damage.
6.Replace
oil
fill
cap/dipstick
and
fully
tighten.
7.Reinstall
maintenance
cover
and
tighten
screws.
8.Oil
level
should
be
checked
prior
to
each
use
or
at
least
every
8
hours
of
operation.
Keep
oil
level
maintained.
Low
Oil
Shutdown
The
portable
generator
is
equipped
with
a
low
oil
shutdown.
If
the
oil
level
drops
below
the
minimum
required
level,
a
sensor
will
activate
an
internal
switch
stopping
the
engine.
If
the
engine
shuts
off
and
the
oil
level
is
within
specifications,
check
to
see
if
generator
is
sitting
at
an
angle.
Place
portable
generator
on
an
even
surface
to
correct
this.
If
engine
fails
to
start,
the
oil
level
may
not
be
high
enough
to
deactivate
the
internal
low
oil
level
switch.
Make
sure
the
sump
is
completely
full
of
oil
to
the
upper
limit
(H).
Do
not
operate
engine
until
oil
level
issue
is
corrected.
Contact
Firman
customer
service.
Add
Gasoline
:fi..
WARN INC! Fuel
and
its
vapors
are
extremely
flammable
which
could
cause
burns
or
fire
~
resulting
in
death
or
serious
injury.
e
Turn
generator
engine
OFF
and
let
it
cool
at
least
2
minutes
before
removing
fuel
cap.
e
Do
Not
refuel
or
move
generator
when
engine
is
running.
e
Move
generator
outdoors
prior
to
adding
or
draining
fuel
e
Keep
fuel
away
from
any
ignition
sources.
e
Do
not
overfill
tank,
allow
space
for
fuel
expansion.
e
If
any
fuel
spills,
wait
until
it
evaporates
before
starting
engine
e
Check
and
replace
fuel
lines,
tank,
cap,
and
fittings
prior
to
each
use
if
any
damage
or
leaks
are
found.
Fuel
must
meet
these
requirements:
e
Clean,
fresh,
unleaded
gasoline
with
a
minimum
of
87
octane.
e
For
high
altitude
use,
see
Operation
at
High
Altitude.
e
Gasoline
with
no
more
than
10%
ethanol
is
acceptable.
English
14
E10
E15
Customer
Service 1-844-FIRMAN1
background
OPERATION
NOTICE
Do
not
mix
oil
in
gasoline
or
modify
engine
to
run
on
alternate
fuels
not
described
in
this
manua
I.
Use
of
unapproved
fuels
could
damage
engine
and
will
not
be
covered
underwarranty.
1.
Clean
area
around
fuel
fill
cap,
remove
cap.
2.
Slowly
add
unleaded
fuel
to
fuel
tank.
Be
careful
not
to
fill
above
the
RED
fuel
level
indicator.
This
allows
adequate
space
for
fuel
expansion.
3.
Install
fuel
cap
and
let
any
spilled
fuel
evaporate
before
starting
engine.
Operation
at
High
Altitude
At
altitudes
over
5,000
feet(1524
meters),
a
minimum
85
octane
gasoline
is
acceptable.
Engine
power
and
generator
output
will
be
reduced
approximately
3.5%
for
every
1000
feet
(305
m)
of
elevation
above
sea
level.
High
altitude
may
cause
hard
starting,
increased
fuel
consumption
and
sparkplug
fouling.
To
operate
at
high
altitudes
FIRMAN
can
provide
a
high
altitude
carburetor
main
jet.
The
alternative
main
jet
and
installation
instructions
can
be
obtained
by
contacting
Customer
Support.
193cc
Altitude
Altitude
main
jet
1
333717004
3000-G000Feet
Altitude
main
jet
2
333717005
6000-S000Feet
NOTICE
Operation
using
an
alternative
main
jet
at
elevations
lower
than
the
recommended
minimum
altitude
can
damage
the
engine.
For
operation
at
lower
elevations,
the
standard
main
jet
supplied
must
be
used.
Operating
the
engine
with
the
wrong
main
jet
may
increase
exhaust
emissions,
fuel
consumption
and
reduce
performance.
Operation
at
High
Ambient
conditions
Your
Firman
Power
Equipment
product
is
designed
and
rated
for
continuous
operation
at
ambient
temperatures
up
to
104°F
(40°C).
The
generator
may
be
operated
at
temperatures
ranging
from
5°F(-15°C)
to
122°F(50°C)
for
short
periods.
If
the
generator
is
exposed
to
temperatures
outside
this
range
during
storage,
the
generator
should
be
brought
back
within
this
range
before
operation.
When
operated
above
77°F(25°C)
there
may
be
a
decrease
in
power.
Maximum
wattage
and
current
are
subject
to
and
limited
by
such
factors
as
ambient
temperature,
altitude,
engine
conditions
etc.
English
15
Customer
Service 1-844-FIRMAN1
background
OPERATION
Connecting
LPG
Fuel
~
WARNING!
Liquid
Petroleum
gas
(LPG)
is
extremely
flammable
which
could
cause
burns
or
fire
resulting
in
death
or
serious
injury.
The
fuel
supply
line
must
always
be
shut
off
when
the
engine
is
not
running.
Failure
to
shut
off
fuel
may
allow
fuel
to
leak
at
the
generator.
Do
not
place
the
LPG
sources
in
the
path
of
muffler
outlet
or
near
any
ignition
source.
Keep
a
fire
extinguisher
near
the
generator
all
the
time.
Do
not
use
or
store
LPG
portable
sources
not
in
use
near
generator
or
in
a
building,
garage
or
enclosed
area.
All
LPG
supply/
piping
lines
must
be
installed
by
a
qualified
plumber.
If
you
smell
gas,
close
off
all
gas
sources
and
contact
a
qualified
plumber
to
inspect
and
repair
the
LPG.
Prior
to
each
days
first
use
spray
a
soapy
water
solution
on
LPG
fuel
connections
to
check
for
leaks.
Never
use
a
gas
container,
LPG
connector
hose
or
LPG
cylinder
that
appears
to
be
damaged.
Do
not
connect
or
disconnect
the
LPG
source
in
an
enclosed
area.
LPG
is
heavier
than
air
and
can
accumulate
in
confined/
low
spaces
if
there
is
a
leak.
NOTICE
If
a
fuel
supply
connection
is
necessary
it
must
be
installed
in
accordance
with
all
local
codes
or
regulations,
or
in
the
absence
of
local
codes
or
regulations,
in
accordance
with
the
National
Fuel
Gas
Code
(NFPA
54/ANSI
2223.1)
and
CSA
B149.1
(Natural
Gas
and
Propane
Installation
Code].
as
applicable.If
possible
the
fuel
supply
connection
should
be
close
to
the
outdoor
operating
location.
This
will
reduce
the
cost
of
the
flexible
fuel
run.
An
approved
flexible
fuel
line
must
be
installed
between
the
generator
LPG
Hose
Connector
(Inlet)
and
the
fuel
supply
connection.In
no
case
should
this
information
be
interpreted
to
conflict
with
any
local,
state,
or
national
code.
If
in
doubt,
always
follow
local
codes.
lPG
Always
keep
the
LPG
cylinder
in
an
upright
position.
Use
only
DOT LPG
cylinders
in
vapor
service
with
type
1,
right
hand
ACME
threads.
Verify
the
re-qualification
date
on
the
cylinder
has
not
expired.
All
new
cylinders
must
be
purged
of
air
and
moisture
prior
to
filling.
The
purging
process
should
be
done
by
your
propane
gas
supplier.
Attach
the
LPG
regulator
hose
assembly
(included)
to
the
LPG
hose
connector
(inlet)
on
the
control
panel
of
the
generator.
Tighten
the
nut
with
a
19
mm
or
adjustable
wrench.
Remove
the
safety
plug
or
cap
from
the
LPG
cylinder
valve.
Attach
the
LPG
regulator
to
the
cylinder
valve.
Do
not
use
a
wrench
to
tighten
LPG
cylinder
nut.
Tighten
the
nut
by
hand
clockwise
to
a
positive
stop.
Using
a
wrench
may
damage
LPG
cylinder
components.
English
16
Customer
Service 1-844-FIRMAN1
background
OPERATION
3.Starting
the
Generator
on
Gasoline
1.
Before
starting
the
generator,
check
for
loose
or
missing
parts
and
for
any
damage
which
may
have
occurred
during
shipment.
Ensure
spark
plug,
muffler,
fuel
cap,
and
air
cleaner
are
all
in
place.
2.
Move
portable
generator
outdoors
to
safe
operating
location
downwind
and
at
least
20
ft.(6
m)
from
any
occupied
spaces.
3.lf
connected
make
sure
the
LPG
cylinder
knob
is
fully
closed
or
disconnected.
4.
Disconnect
all
electrical
loads
from
the
generator.
Never
start
or
stop
the
generator
with
electrical
devices
plugged
in.
5.
Turn
the
main
fuel
selector
switch
to
"GAS"
position(4:30
o'clock).
~
GAi
i1
6.
Flip
the
engine
switch
to
the
"RUN"(I)
position.
7. Push
the
battery
power
restore
switch
for
about
3 seconds
and
then
release.
English
17
Customer
Service 1-844-FIRMAN1
background
OPERATION
8.
Pull
the
choke
knob
out
to
the
""START"'
position.
You
do
not
need
to
choke
a
warm
engine.
(For
electric
start
move
to
step
(10))
9.
For
recoil
start
only-Pu
I I
the
starter
cord
slowly
until
resista
nee
is
felt
and
then
pu
II
rapidly
to
start
engine.
10.
For
electric
start
only-Flip
the
engine
switch
to
the
START (II)
position
for
a
few
seconds
and
then
release.
II
l$j
11.
Do
not
over-choke.
As
soon
as
engine
starts
and
warms
up,
move
the
choke
knob
to
the
"RUN"
position.
I+
I
12.
Allow
portable
generator
to
run
at
no
load
for
a
few
minutes
to
stabilize
before
plugging
in
any
electrical
devices.
NOTICE
If
engine
starts
but
fails
to
run,
orif
portable
generator
shuts
down
during
operation,
check
oil
level.
See
Low
Oil
Shutdown
section
for
more
information.
The
gasoline
valve
is
OPEN,
when
the
fuel
selector
switch
is
in
"GAS"
position(4:30
o·cIock).
To
close
this
valve,
turn
the
slector
switch
to
the··
LPG"
position
(1:30
o'clock).
English
18
Customer
Service 1-844-FIRMAN1
background
OPERATION
4.Starting
the
Generator
on
LPG
l.
Before
starting
the
generator,
check
for
loose
or
missing
parts
and
for
any
damage
which
may
have
occurred
during
shipment.
Ensure
spark
plug,
muffler,
fuel
cap,
and
air
cleaner
are
all
in
place.
2.
Move
portable
generator
outdoors
to
safe
operating
location
downwind
and
at
least
20
ft.(6
m)
from
any
occupied
spaces.
3.
Connect
the
LPG
hose
with
regulator
to
both
LPG
cylinder
and
portable
generator
LPG
Hose
Connector
(in
let).
LPG
4.
Fully
open
the
LPG
cylinder
knob.
5.
Disconnect
a
II
electrica
I
loads
from
the
generator.
Never
start
or
stop
the
generator
with
electrical
devices
plugged
in.
6.
Turn
the
main
fuel
selector
switch
to
LPG
position(l:30
o'clock).
Engli
sh
19
Custo
mer
Service 1-844-FIRMA
N1
background
OPERATION
7. Flip
the
engine
switch
to
the
"'RUN"(I)
position.
8.
Push
the
battery
power
restore
switch
for
about
3
seconds
and
then
release.
9.
Pull
the
choke
knob
out
to
the
"START"
position.(Forelectricstart
move
to
step
(13))
10.
For
recoil
start
only-
PULL-TO-PRIME
Pull
the
starter
cord
1-2
times.
Pull
slowly
until
resistance
if
felt
and
then
pull
rapidly.
11.
For
recoi
I
start
only
-
Move
the
choke
knob
to
the
"RUN··
position.
English 20
Customer
Service 1-844-FIRMAN1
background
OPERATION
12.
For
recoil
start
only-
PULL-TO-RUN
Pull
the
starter
cord
slowly
until
resistance
if
felt
and
pull
rapidly
to
run
the
portable
generator.
If
the
engine
fails
to
start
in
1-2
pulls
with
choke
in
the
RUN
position,
move
choke
knob
to
START
position
and
repeat
the
PULL-TO-PRIME
step
(10).
13.
For
electric
start
only-Flip
the
engine
switch
to
the
START
(11)
position
for
a
few
seconds
and
then
release.
II
~
14.
For
electric
start
only
-
Move
the
choke
knob
to
the
RUN
position.
15.
Al
low
portable
generator
to
run
at
no
load
for
a
few
minutes
to
stabilize
before
plugging
in
any
electrica
I
devices.
NOTICE
If
engine
starts
but
fails
to
run,
orif
portable
generator
shuts
down
during
operation,
check
oil
level.
See
Low
Oil
Shutdown
section
for
more
information.
NOTICE
Observing
frost
on
LPG
cylinder
and
regulator
is
common
during
operation
and
normally
is
not
an
indication
of
a
problem.
In
unusual
situations
this
frost
may
eventually
restrict
the
flow
of
LPG
gas
to
the
generator
resulting
in
deteriorating
performance.
In
these
rare
situations
it
can
be
helpful
to:
Exchanging
fuel
cylinders
to
allow
the
first
cylinder
to
warm
up,
repeating
as
necessary.
Placing
the
LPG
cylinder
at
the
end
of
the
generator
near
the
handle,
where
engine
fan
airflows
out
from
the
generator.
This
air
is
slightly
heated
by
air
flowing
over
the
engine.
Do
not
place
the
LPG
cylinder
in
the
path
of
the
muffler
exhaust
outlet.
The
LPG
cylinder
and
components
can
be
temporarily
warmed
by
pouring
warm
water
over
them.
English
21
Customer
Service 1-844-FIRMAN1
background
OPERATION
5.
Connecting
Electrical
Loads
This
inverter
generator
has
been
pretested
and
adjusted
to
handle
its
full
capacity.
A A
WASN
,Ne,
Geoe,aCo"o"age
co""""'"
e,ewka,
s,
00
,
0
,o"m
~
-
resulting
in
death
or
serious
injury.
Damaged
or
overloaded
extension
cords
cou
Id
overheat,
arc,
and
burn
resulting
death
or
serious
injury.
Use
a
ground
fau
It
circuit
interrupter
(GFCI)
in
any
damp
or
highly
conductive
area,
such
as
metal
decking.
Do
not
touch
bare
wires
or
receptacles.
Do
not
use
generator
with
electrica
I
cords
which
are
worn
,
frayed,
bare
or
otherwise
damaged.
Do
not
operate
generator
in
the
rain
or
wet
weather.
Do
not
run
indoors
to
avoid
wet
conditions.
Do
not
handle
generator
or
electrical
cords
while
standing
in
water,
while
barefoot,
or
while
hands
or
feet
are
wet.
I.Ensure
circuit
breaker
on
control
panel
is
in
the
closed
(on)
position.
2.
Start
the
generator
with
no
electrical
load
attached.
3.
Allow
the
engine
to
run
for
several
minutes
to
stabilize.
4.
Plug
in
and
turn
on
the
first
item.
It
is
best
to
attach
the
item
with
the
largest
load
first.
5.
Allow
the
engine
to
stabilize.
6.
Plug
in
and
turn
on
the
next
item.
7.
Allow
the
engine
to
stabilize.
8.
Repeat
steps
5-6
for
each
additional
item.
Surge
Protection
There
is
a
remote
chance
that
voltage
fluctuations
may
impair
the
proper
functioning
of
some
sensitive
electronic
equipment.
Electronic
devices,
including
computers
and
many
programmable
appliances
may
use
components
that
are
designed
to
operate
within
a
narrow
voltage
range
and
may
be
affected
by
the
portable
generator's
momentary
voltage
fluctuations.
While
there
is
no
way
to
prevent
all
voltage
fluctuations,
you
can
take
steps
to
protect
your
sensitive
electronic
equipment.
Install
a
plug-in
surge
suppressor
on
the
receptacles
feeding
your
sensitive
equipment.
Surge
suppressors
come
in
single
or
multi-outlet
styles.
They
are
designed
to
protect
against
short
duration
voltage
fluctuations.
English
22
Customer
Service 1-844-FIRMAN1
background
OPERATION
CO
Alert
TM
Carbon
Monoxide
(CO)
Shutdown
System
CO
Alert
automatically
shuts
down
the
engine
when
harmful
levels
of
carbon
monox
i
de
accumulate
around
the
generator
or
a
CO
Alert
fault
occurs
.
After
shutdown,
the
CO
Alert
indicator
light
will
blink
for
at
least
five
minutes
per
the
chart
below.
CO
Alert
DOES
NOT
replace
carbon
monoxide
alarms.
Install
battery-powered
carbon
monoxide
alarm(s)
in
your
home.
Don
't
run
generator
in
enclosed
are
as.
Color
Description
Carbon
monoxide
accumulated
around
generator.
Prior
to
restart
move
generator
to
an
open,
outdoor
area
downwind
and
at
least
20
ft.
(6
m)
from
occupied
spaces
with
exhaust
pointed
away.
Air
out
premises
(open
Red
windows
and
doors)
before
reoccupying
property
.
•••••
Automatic
shutoff
is
an
indication
generator
was
improperly
located
.
If
you
start
to
feel
sick,
dizzy,
weak
,
or
your
homes
carbon
monoxide
alarm
sounds
while
using
this
product,
get
to
fresh
air
right
away.
Call
emergency
services.
You
may
have
carbon
monoxide
poisoning.
Yellow
CO
Alert
fault
occured•.
••
••
See
Fl
RMAN
authorized
service
dealer
.
*
Yellow
light
will
blink
for
five
seconds
at
the
startup
of
generator
to
show
CO
ALERT
is
functioning
properly
.
Eng
li
sh 23 Customer Servi
ce
: 1-844-FIRMAN 1
background
OPERATION
Economy
Control
Switch
The
Economy
Control
switch
can
be
activated
in
order
to
minimize
fuel
consumption
and
noise
while
operating
the
unit
during
times
of
reduced
electrical
output,
allowing
the
engine
speed
to
idle
during
periods
of
non-use.
The
engine
speed
returns
to
normal
when
an
electrical
load
is
connected.
When
the
economy
switch
is
off,
the
engine
runs
at
normal
speed
continuously.
NOTICE:
o[QJ1
BIIIIE
•m
111•
For
periods
of
high
electrical
load
or
momentary
fluctuations,
the
Economy
Control
Switch
should
be
turned
OFF.
12V
DC
Outlet
(Battery
Charger)
The
12V DC
outlet
is
ONLY
to
be
used
with
the
supplied
12V
battery
charging
cable.
The
DC
output
is
unregulated
and
will
damage
other
12V
DC
products.
The
amount
of
current
flowing
will
depend
on
the
charging
voltage
and
battery's
state
of
charge.
As
the
battery
becomes
more
fully
charged,
the
output
current
to
the
battery
decreases
and
nearly
becomes
constant.
Taper
chargers
are
intended
to
be
used
with
the
provision
that
they
will
be
disconnected
from
the
battery
after
a
maximum
time
on
charge.
Normally
a
period
of
30
to
120
minutes
is
sufficient
to
recharge
a
weak
battery.
The
charge
level
of
the
battery
should
be
checked
periodically.
For
use
with
12V
direct
current
outlet,
always
keep
the
ECO
mode
deactivated
(OFF
Position
).
You
can
use
the
12V
directcurrentoutletand
the
120Vcurrentat
the
same
time,
but
keep
the
ECO
mode
deactivated
(OFF
Position]
at
all
times.
Do
not
start
the
vehicle
while
the
battery
charging
Cable
is
connected
and
the
generator
is
running
.
It
will
not
give
the
battery
a
boost
of
power.
The
Vehicle
or
the
generator
may
be
damaged.
Charge
only
vented
wet
lead
acid
batteries.
Other
types
of
batteries
may
burst,
causing
personal
injury
or
damage.
WARNING!
Storage
batteries
give
off
EXPLOSIVE
hydrogen
gas
while
charging.
Do
not
allow
smoking,
open
flames,
sparks,
or
spark
producing
equipment
in
the
area
while
charging.
Battery
electrolyte
fluid
is
comprised
of
sulfuric
acid
that
can
be
very
dangerous
and
cause
severe
burns.
Do
not
allow
this
fluid
to
contact
eyes,
skin,
clothing,
etc.
If
contact
or
spillage
does
occur,
flush
the
area
with
water
immediately.
Do
not
continue
to
charge
a
battery
that
becomes
hot
or
is
fully
charged.
1.
Before
connecting
the
battery
charging
cable
to
a
battery
that
is
installed
in
a
vehicle,
disconnect
the
vehicle
battery
ground
cable
from
the
negative(-)
battery
terminal.
2. Plug
the
battery
charging
cable
into
the
DC
receptacle
of
the
generator.
3.
Connect
the
red(+)
battery
charger
lead
to
the
red(+)
battery
terminal.
4.
Connect
the
black(-)
battery
charger
lead
to
the
black(-)
battery
terminal.
5.
Start
the
generator.
English
24
Customer Service: 1-844-FIRMAN 1
background
OPERATION
6.
Stopping
the
generator
1.
Turn
off
and
remove
all
electrical
loads.
Never
stop
the
generator
with
electrica
Id
evices
plugged
in
and
turned
on.
Never
stop
the
engine
by
moving
the
choke
to
the
start
position.
Let
the
generator
run
at
no-load
for
one
minute
to
stabilize
internal
temperatures
of
the
engine
and
generator.
2. Flip
the
engine
switch
to"OFF"(O]
position.
3.
Turn
the
main
fuel
selector
switch
to
"LPC"
position
(1:30
o'clock).
The
gasoline
valve
is
closed
in
this
position.
4.
Fully
close
the
LPG
cylinder
knob.
If
a
cover
is used,
do
not
install
until
unit
has
cooled.
NOTICE
Disconnect
the
LPG
cylinder
from
the
generator
during
transportation.
English
25
Customer
Service 1-844-FIRMAN1
background
OPERATION
Low
Oil
Shutdown
If
the
engine
oil
drops
below
a
preset
level,
an
oil
switch
will
stop
the
engine.
Check
oil
level
with
dipstick.
If
oil
level
is
between
the
LOW
and
HICH
mark
on
dipstick:
l.DO
NOT
try
to
restart
the
engine.
2.Contactan
Authorized
FIRMAN
Service
Dealer.
3.DO NOT
operate
engine
until
oil
level
is
corrected.
If
oil
level
is
below
the
LOW
mark
on
dipstick:
l.Add
oil
to
bring
level
to
HICH
mark.
2.Resta
rt
engine
and
if
the
engine
stops
again
a
low
oil
condition
may
still
exist.
DO
NOT
try
to
res
ta
rt
the
engine.
3.Contact
an
Authorized
FIRMAN
Service
Dealer.
4.DO
NOT
operate
engine
until
oil
level
is
corrected.
Do
Not
Overload
Generator
Overloading
a
generator
in
excess
of
its
rated
wattage
capacity
can
result
in
damage
to
the
generator
and
to
connected
electrical
devices.
To
prolong
the
life
of
your
generator
and
attached
devices,
follow
these
steps
to
add
electrical
load:
l.
Start
the
generator
with
no
electrical
load
attached.
2.
Allow
the
engine
to
run
for
several
minutes
to
stabilize.
3.
Plug
in
and
turn
on
the
first
item.
It
is
best
to
attach
the
item
with
the
largest
load
first.
4.
Allow
the
engine
to
stabilize.
5.
Plug
in
and
turn
on
the
next
item.
6.
Allow
thee
ngine
to
stabilize.
7.
Repeat
steps
5-6
for
each
additional
item.
Overload
Operation
The
overload
indicator
light
will
blink
when
the
load
exceeds
3550W(approximately)
and
cut
power
to
the
receptacles
in
30
seconds.
If
the
load
exceeds
3680W(approximately).
the
light
will
turn
on
and
cut
power
to
the
receptacles
in
2
seconds.
How
to
Correct
1.
Disconnect
any
electrical
devices,
and
then
stop
the
engine.
2.
Reduce
the
total
wattage
of
connected
electrical
devices
until
it
is
within
the
generator's
rated
output.
3.
Inspect
the
Air
Inlet
and
Control
Panel
for
any
blockage.
Remove
blockage
if
found.
4.
Restart
Engine.
Parallel
Operation
Any
two
Fl
RMAN
inverter
generators
with
para I lel ports,
including
two
Fl
RMAN
inverters
model
WH03342
can
be
paralleled
to
increase
the
total
available
electrical
power
to
6000
Watts.
A FIRMAN Parallel
kit
(not
included)
is required
for
parallel
operation.
For
Kit
availability, call
customer
Service
at
1-844-
347-6261
or
visit:
www.firmanpowerequipment.com.
English 26
Customer
Service 1-844-FIRMAN1
background
Maintenance
-
Storage
MAINTENANCE
SCHEDULE
Every
ITEM
NOTES
Daily(Before
Initial Every
100 hours
Every
operation)
25
hours
50
hours
(or annual)
250
hours
Spark
Plug
Check
condition.
Adjust
gap
and
clean. Replace
if
necessary.
Check
oil
level.
Engine
Oil
Replace.
Air
Filter
Clean, replace
if
necessary.
Clean
fuel
tank
strainer.
Fuel
Replace
if
necessary.
Fuel Line
Check
fuel
hose
for
cracks
or
other
damage.
Replace
if
necessary.
LPG
Regulator
Check
for
damage
and
leaks.
/HoseAssy.
Replace
if
necessary.
Check
for
leakage.
Retighten
or
Exhaust
replace
gasket
if
necessary.
System
Check
spark
arrester
screen.
Clean/Replace
if
necessary.
Check
adjust
valve
clearance.
.
Engine
Clean
combustion
chamber.
.
Fittings/
Fasteners
Check. Replace
if
necessary.
•Tobe
performed
by
knowledgable/experienced
owner
or
by
authorized
service
center.
General
Recommendations
Regular
maintenance
will
improve
the
performance
and
extend
the
life
of
the
generator.
See
any
authorized
dealer
for
service.
The
generator's
warranty
does
not
cover
items
that
have
been
subjected
to
operator
abuse
or
negligence.
To
receive
full
value
from
the
warranty,
the
operator
must
maintain
the
generator
as
instructed
in
this
manual.
Some
adjustments
will
need
to
be
made
periodically
to
properly
maintain
your
generator.
All
service
and
adjustments
should
be
made
at
least
once
each
season.
Follow
the
requirements
in
the
maintenanc
shedule
chart
above.
NOTICE
Once
a
year
you
should
clean
or
replace
the
spark
plug
and
replace
the
air
filter.
New
spark
plug
and
clean
air
filter
assure
proper
fuel-air
mixture
and
help
your
engine
run
at
peak
performance
and
last
longer.
English 27
Customer
Service 1-844-FIRMAN1
background
Maintenance
-
Storage
When
Transporting
Generator
Transport
with
fuel
tank
EMPTY
or
with
fuel
switch
in
OFF
position.
Do
not
tip
generator
at
an
angle
which
causes
fuel
to
spill.
EN
CINE
MAINTENANCE
To
prevent
accidental
starting,
remove
and
ground
spark
plug
wire
before
performing
any
service.
Change
Engine
Oil
Change
engine
oil
every
100
hours.
(for
a
new
engine
,
change
oi
I
after
25
hours.)
If
you
a
re
using
your
generator
under
extremely
dirty
or
dusty
conditions,
or
in
extremely
hot
weather
change
the
oil
more
often.
CAUTION!
Avoid
prolonged
or
repeated
skin
contact
with
used
motor
oil.
Used
motor
oil
has
been
shown
to
cause
skin
cancer
in
certain
laboratory
animals.
Thoroughly
wash
exposed
areas
with
soap
and
water.
A KEEP OUT OF REACH
OF
CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL
WTO
COLLECTION CENTERS.
(a) Loosen
the
cover
screws
and
remove
the
maintenance
cover.
(bl
Pop
up
the
rubber
plug
from
below
yellow
draining
bolt.
(c)
Remove
yellow
drain
bolt.
(d)
Tilt
the
generator
on
its
side
and
allow
the
oil
to
drain
completely.
(e) Replace
yellow
drain
bolt.
(f) Fill
the
engine
with
oil
until
it
reaches
the
HIGH(H) level
on
the
oil
filler
cap. DO NOT OVERFILL.
NOTICE
We
recommend
using
SAE
I0W-30
API
SL
or
higher
oil
f
or
best
performance.
Do
not
use
special
additives.
See
Oil
and
Casoline
/ LPC.
Engli
sh 28 Custo
mer
Service 1-844-FIRMA
N1
background
Maintenance
-
Storage
Air
Filter
Maintenance
(a)
Remove
the
air
cleaner
cover
and
locate
the
air
filter
plastic
cover.
(b)
Carefully
remove
foam
air
filter
element
and
wash
it
with
liquid
detergent
and
water
o
nly.
Squeeze
dry
in
a
clean
cloth.
( c)
Saturate
foam
air
filter
element
with
clean
engine
oil
and
squeeze
in
a
clean
cloth
to
remove
excess
oil.
AIR
FILTER
ELEMENT
(d)
Reinstal
I
clean
or
new
air
filter
element.
(e)
Reattach
the
air
filter
cover.
(f)
Reinstall
the
air
cleaner
cover
and
tighten
the
cover
screw
securely.
Spark
Plug
Maintenance
Changing
the
spark
plug
will
help
your
engine
start
easier
and
run
at
peak
performance.
(a)
Remove
the
maintenance
cover.
(b)
Remove
the
spark
plug
boot.
(c)
Remove
spark
plug
using
provided
wrench.
English 29 Custo
me
r Service 1-844-FIRMA
N1
background
Maintenance
-
Storage
(d)
Inspect
spark
plug
for
damage
and
clean
with
a
wire
brush
before
reinstalling.
Replace
if
damaged.
(e)
For
spark
plug
Fl
RMAN
P
/N
330723001
-Adjust
the
electrode
gap
to
0.020
-
0.024
in.
( 0.5 -
0.6
mm).
(f)
Seat
spark
plug
in
position
and
thread
by
hand
to
prevent
cross
threading.
(g)
Tighten
plug
with
provided
wrench
and
put
the
spark
plug
boot
back
on
spark
plug.
SIDE
ELECTllODE
..___,._0.020-0.024
in.
(0.5-0.6mm)
SEALING
WASHER
SPARK PLUG:
FIRMAN
P/N
330723001
SPARK PLUG:
Fl
RMAN
P/N
330723001
Maintenance
Valve
Clearance
Intake:
0.004
-
0.006
in.
(0.10
- 0.15
mm)
Exhaust:
0.004
-
0.006
in.
(0.10
- 0.15
mm)
Muffler
and
Spark
Arrester
~
WARN
INC!
Contact
with
muffler
area
could
cause
burns
resulting
in
serious
injury.
Do
not
touch
hot
parts.
It
is
a
violation
of
California
Public
Resource
Code,
Section
4442,
to
use
or
operate
the
engine
on
any
forest-covered,
brush-covered,
or
grass-covered
land
unless
the
exhaust
system
is
equipped
with
a
spark
arrester,
as
defined
in
Section
4442,
maintained
in
effective
working
order.
Other
states
or
federal
jurisdictions
may
have
similar
laws,
reference
Federal
Regulation
36
CFR
Part
261.52.
English 30
Customer
Service 1-844-FIRMAN1
background
Maintenance
-
Storage
Inspect
Muffler
and
Spark
Arrester
I.Inspect
the
muffler
for
cracks,
corrosion,
or
other
damage.
2.
Loosen
the
spark
arrester
clamp,
remove
the
spark
arrester
cover,
and
remove
the
spark
arreste
r
with
a
thin
blade
screwdriver.
3.
Carefully
remove
the
carbon
deposits
from
the
spark
arrester
screen
with
a
wire
brush.
4.
Replace
the
spark
arrester
if
it
is
damaged.
If
replacement
parts
are
required,
make
sure
to
use
only
FIRMAN
original
equipment
replacement
parts.
5.
Position
the
spark
arrester
in
the
muffler
and
attach
spark
arrester
cover
with
the
screws.
NOT/CE
Failure
to
clean
or
replace
spark
arrester
may
result
in
decreased
engine
performance.
CENERATOR
MAINTENANCE
Run
the
generator
at
least
30
minutes
every
month.
Make
certa
i n
that
the
portable
generator
is
kept
clean
and
dry.
Do
not
expose
the
unit
to
excessive
dust,
dirt,
moisture
or
corrosive
vapors.
Do
not
insert
any
objects
through
cooling
slots.
Before
each
use
inspect
underneath
the
gene
r
ator
for
signs
of
oil
or
fuel.
Clean
any
accumulated
debr
is.
Keep
area
around
muffler
free
from
any
debris
. Use a
soft
bristle
brush
to
remove
di
rt
or
caked
on
oil.
Use
a
damp
cloth
to
clean
all
exterior
surfaces.
Eng
li
sh 31 Custom
er
Servi
ce
: 1-844-FIRMAN 1
background
Maintenance
-
Storage
Battery
Replacement
I.Unscrew
the
air
cleaner
cover
by
provided
screwdr
i
ver
.
2.
Release
the
battery
retaining
rubber
belt.
3.
Remove
the
protective
cover(rubbersheath)
from
battery.
4.
Disconnect
the
black(-)
cable
from
black(-)
terminal
on
the
battery.
Disconnect
the
red(
+)
cable
from
red(
+)
terminal
on
the
battery.
Battery
Red Cable
Terminal
5.
Remove
the
battery
and
recycle
and
dispose
of
proper
ly.
6.
Install
the
new
battery
with
following
specification,
12V
sealed
lead
acid
5.SAH
LXWXH:3.54X2.76X3.84
in
.
(90X70X100mm)
7.
Connect
the
red(+
)batterycable
to
the
positive
terminal
of
battery
first
and
then
connect
the
black(-)
battery
cable
to
the
negative
terminal
of
battery.
8. Reattach
the
air
cleaner
cover.
Eng
li
sh 32 Customer Servi
ce
: 1-844-FIRMAN 1
background
Maintenance
-
Storage
Battery
Charging
The
battery
powers
the
starter
motor
and
control
module.
This
portable
generator
is
equipped
with
an
automatic
battery
charging
circuit.
The
battery
will
receive
charging
voltage
only
when
the
engine
is
running.
The
battery
will
maintain
a
proper
charge
if
the
portable
generator
is
used
on
a
regular
basis
(about
once
every
two
weeks).
If
it
is
used
less
frequently,
we
can
use
the
supplied
charger
plugged
into
the
generator
12VDC
Battery
Charge
Port
to
charge
the
battery.
l.
Plug
the
cord
from
the
charger
into
the
charging
port
on
the
generator
control
panel.
2.
Plug
the
charger
into
a 120
volt
AC
wall
outlet.
3.
The
re
is
a
light
on
the
charger
that
rem
a
ins
red
until
the
battery
is
fully
charged
at
which
point
the
light
will
turn
green.
English 33
Customer
Service 1-844-FIRMAN1
background
Maintenance
-
Storage
Long
Term
Storage
It
is
important
to
prevent
gum
deposits
from
forming
in
essential
fuel
system
components
such
as
the
carburetor,
fuel
hoses
or
tank
during
storage.
Ethanol-blended
fuels
(called
gasohol,
ethanol
or
methanol)
attract
moisture,
which
leads
to
separation
and
formation
of
acids
during
storage.
Acidic
gas
can
damage
the
fuel
system
of
an
engine
while
in
storage.
When
the
generator
set
is
being
stored
for
more
than
one
month,
follow
these
instructions
to
avoid
engine
problems:
WARN
INC!
Fuel
and
its
vapors
are
extremely
flammable
which
could
cause
burns
or
fire
resulting
ind
eath
or
serious
injury.
Do
not
store
fuel
near
any
ignition
sources.
When
draining
fuel
move
generator
outdoors
and
use
a
commercially
available
non-conductive
vacuum
siphon.
Fuel
must
be
drained
into
an
approved
container.
1-Treat
any
stored
fuel
with
fuel
stabilizer.
2-When
storing
generator
with
gasoline
in
fuel
tank,
operate
the
engine
for
5-10
minutes
to
circulate
treated
fuel
into
fuel
lines
and
carburetor
before
shutdown.
3-
There
is
no
need
to
drain
gasoline
from
the
generator
fuel
tank
if
fuel
stabilizer
is
added.
4-FUEL
STARVATION:
If
you
elect
to
drain
fuel
tank
move
generator
outdoors.
Once
fuel
tank
is
drained
turn
fuel
valve
to
on
position.
Start
and
run
the
portable
generator
outdoors
until
engine
stops
from
lack
of
gasoline.
This
will
drain
remaining
gasoline
from
tank,
fuel
lines,
and
carburetor.
5-Always
turn
fuel
valve
to
OFF
position
prior
to
storage.
6-Allow
the
portable
generator
to
cool
before
cleaning
and
storage.
7-Change
oil.
8-Remove
spark
plug
boot
and
spark
plug.
Pour
a
bout
one
teaspoon
of
engine
oil
through
the
spark
plug
hole,
then
slowly
pull
the
recoil
starter
several
times
to
distribute
the
oil
in
the
cylinder
Pull
recoil
slowly
until
resistance
is
felt.
This
will
close
the
valves
so
no
moisture
enters
the
engine
cylinder.
Reinstall
the
spark
plug
and
attach
the
spark
plug
boot.
9-Cover
the
portable
generator
and
store
in
a
clean,
dry
place
out
of
direct
sun
light
and
away
from
any
ignition
sources.
Any
damage
or
hazards
caused
by
using
improper
fuel,
improperly
stored
fuel,
and/or
improperly
formulated
stabilizers,
are
not
covered
by
manufacturer's
warranty.
Do
not
store
gasoline
from
one
season
to
another
season.
English
34
Customer
Service 1-844-FIRMAN1
background
Troubleshooting
-
Specifications
Problem Cause Correction
1. Circuit breaker is open.
1.
Reset
circuit
brea
ker.
2.
Fau
lt
in
generator.
2.
Contact authorized service facility.
Engine
is
running,
but
no
3.
Poor connection or defective cord
set.
3. Check and repair.
AC
output
is available.
4. Connected device is
bad.
4. Connect another device that is in
5.
Overload.
good condition.
5.
Shut
off
engine, reduce electrical
load, and resta rt.
1. Short circuit in a connected load.
1.
Disconnect shorted electrical load.
Engine runs good
at
2. Engine
speed
is
too
slow.
2.
Contact authorized
service
facility.
no-load
but
"bogs down"
3. Shorted generator circuit.
3.
Contact authorized
service
facility.
when loads are connected.
4.
Clogged
or
dirty
fuel
filter.
4.
Clean
or
re
p
lace
fuel filter.
1.
Fuel
selector
switch
set
to
OFF
(0
1.
Set
fuel
selector
switch
to
"GAS"
position.
or
"LPG"
position.
2.
Low
oil
level.
2.
Fill crankcase
to
proper
level
or
place
generator
on
level surface.
3.
Dirty
air
cleaner.
3.
Clean
or
replace
air
cleaner.
4.
Out
of
gasoline.
4.
Fill
fuel
tank
with
gasoline.
Engine will
not
start; starts
5.
Stale gasoline.
5.
Drain fuel
tank
and carburetor; fill
and runs rough
or
shuts
6. Spark plug
wire
not
connected
to
with
fresh gasoline.
down
when
running.
spark
plug.
6.
Connect
wire
to
spark
plug.
7. Bad
spark
plug.
7.
Replace spark plug.
8.
Water
in
gasoline. 8. Drain gas
tank
and carburetor; fill
with
fresh gasoline.
9. Flooded.
9.
Wait
5 minutes and re-crank engine.
10. Excessively
rich
fuel
mixture.
10.
Contact
authorized service facility.
11.
Clogged
or
dirty
fuel
filter.
11.
Clean
or
replace
fuel
filter.
12.
Starting
battery
may
have
12.
Check
battery
output
and
charge
insufficient
charge.
battery
as necessary.
13.
Out
of
LPG.
13.
Replace
LPG
cylinder.
14.
LPG
cylinder
knob
is
not
open.
14.
Fully open
LPG
cylinder
knob.
15.
Out
of
battery
power.
15.
Charge
the
battery.
1.
Load is
too
high.
1.
Don't
Overload
Generator
Engine lacks
power.
2.
Dirty
air
filter.
2.
Replace
air
filter.
3.
Clogged
or
dirty
fuel
filter.
3. Clean
or
replace
fuel
filter.
4.
Clogged
spark
arrester.
4. Clean
or
replace
spark
arrester.
1.
carburetor is ltlnning
too
rich
or
too
lean.
1.
Contact
authorized
service facility.
Engine"hunts"or falters.
2.
Clogged
or
dirty
fuel
filter.
2.
Clean
or
replace
fuel
filter.
1.
Out
of
gasoline
or
LPG.
1.
Fill fuel
tank
with
gasoline
or
replace
LPG
cylinder.
Engine shuts down
when
2.
Dirty
air
cleaner.
2.
Clean
or
replace
air
cleaner.
3.
Low
oil
level.
3.
Fill crankcase
to
proper level
or
place.
running.
generator on level surface.
Engine shuts
down
and
1.
Contact
authorized
FIRMAN
yellow
CO
fault
light
blinking.
1.
CO
system
fau
It
service
facility.
For
all
other
issues,
contact
authorized
dealer
or
Firman
customer
service.
English 35
Customer
Service 1-844-FIRMAN1
background
Troubleshooting
-
Specifications
SPECIFICATIONS
Model
WH03342
Starting
Watts
4125(GASOLINE)/3750(LPG)
Running
Watts•
3300(GASOLI N E)/3000(LPG)
Rated
AC
Voltage
120V
Rated
Fequency
60Hz
Phase
Single
Voltage
Regulator
Digital
Power
Factor
,
Total
Harmonic
Distortion(THD)
<3%
Alternator
Type
Magneto
Inductor
Engine
FIRMAN
Engine
Type
Single
Cylinder,
4-Stroke
OHV
Air
Cooled
Displacement
193cc
Low
Oil
Shutdown
Yes
Ignition
System
Breakless
Ignition
Type,
Flywheel
Magneto
Starting
System
Recoil/Electric
Fuel
Unleaded
Automotive
Gasoline
Capacity
Fuel
Tank
1.8 U.S.
Gallons
(6.8L)
Lubricating
Oil
Capacity
20.3
oz
(0.6L)
Carburetor
Type
Float
Air
Cleaner
Polyurethane
Type
P.T.O.
Shaft
Rotation
Counter
Clockwise
(Facing
P.T.O.)
Oil
Type
See
"Add
Engine
Oil"
Section
AC
Grounding
System
Neutral
Floating
No
Load
Ha
If
Load
Full
Load
LPG
fuel
consumption
6.5ft'
/hr(0.69L
/
hr)
ns
.
Sft
3
/hr(l
.65
L/
hr)
23
.
3ft'
/
hr(2.47L/hr
16,351
BTU/h(4,792W)
39,113
BTU/h
(11
,463
W)
58,576
BTU
/ h(17,167W)
*Generator certified in accordance
with
CSA
(Canadian Standards Association) standard C22.2No.
100-14,
Motors and Generators and complies
with
PGMA
(Portable Generator Manufacturers' Association) standard
ANSI/PGMA G300-2018,
Sa
f
ety
and
Performance
of
Portable Generators.
English 36 Custo
me
r Service 1-844-FIRMA
N1
background
PARTS
DIACRA
WH03342
PARTS
D~A~~~PART
LIST
English 37
Customer
Service: 1-844-FIRMAN1
background
193cc
ENGINE
PARTS
DIAGRAM
~
<
;v!o'
" : ::0~ -o"
" ~
"
Ill
81
<
/~,·~,/
<
:-,·,
~'
';'
/
/
"
" 2
" /
,,/4
,--:
16
m
~Y
II
II
33
14
Ii
35
II
13
21
JI
l.;
I
~
38
English 38
Customer
Service: 1-844-FIRMAN1
background
Parts
Diagrams
-
Parts
Lists
-
Wiring
Diagram
WH03342
Portable
Generator
NO.
Part
Number
Descrintion
Qtv
NO.
Part
Number
Descriotion
Qtv
1
332467001
Engine
1
38.1
336718362
Screw
Msx14
3
2
333757001
Ground
Wire
1
38.2
330713541
Handle.Lower
1
3
330713560
Generator
End
Cover
1
38.3
330713539
Hand
le.Left
1
4
317718304
Bolt
M6x20
3
38.4
333717003
Nut
M6
2
5
332717001
Bolt
M6x45
4
38.5
336713561
Bolt
M6x2s
2
6
332457004
Alternator
Assembly
1
38.6
330713540
Handle,Uooer
1
6.1
332457005
Stator
Assembly
1
38.7
330713528
Handle,Riaht
1
6.2
332457006
Rotor
Assembly
1
39
330713529
Bolt
M8x16
2
7
330713555
Nut
M14 1
40
333717004
Washer
2
8
332727006
Generator
Fan
1
41
330713538
Bracket,
Left
1
9
336723526
Bolt
M6x1s
2
42
333717005
Washer
2
10
330713552
Generator
End
Cover
1
43
330713537
Sunnorter,Left
1
11
330713550
Rubber
Sleeve,
End
Cove
1
44
336718360
Screw
M6x12
4
12 317713521
Screw
St4.8x17
4
45
330713536
Su""Orter,riaht
1
13 317713523
Screw
St4.2xl6
1
46
330713535
Pivot
Bracket
2
14
336718301
Bolt
M6X12 1
47
333717006
Bolt
M6x12
4
15
336713538
Screw
Msx14
2
48
330713532
Bracket.Ria
ht
1
16
330713519
Plate,
Spark
Arrester
1
49
333717007
Washer
2
17
336713536
Soark
Arrester
Assembly
1
50
333727003
Fuel
Pioe
1
18
330713516
Muffler
Assembly
1
51
330713508
Clin
1¢10.5Xb8l
3
19
336718359
Screw
St4.2X9.5
1
53
333727004
Fuel
Pioe
1
20
330713522
Muffler
Protector
Assembly.Upp, 1
54
333717020
Clio(!1l12xb8)
1
21
330713523
Screw
St4.2X16
4
55
333717008
Strainer
1
22
330713515
Muffler
Protector
Assemblv,Lowe
1
56
333717009
Insulation
Hot
1
23
330713523
Screw
St4.2X16
1
57
330713506
Fuel
Tank
1
24
330713514
Gasket,
Exhaust
1
58
336718361
Screw
M6x12
4
25
330713521
Nut
M6
2
59
333427007
Fuel
Filter
Assemb
Iv
1
26
330713523
Screw
St4.2x16
1
60
333427004
Too
Cover
1
27
333427001
Rear
Cover
1
60.1
330713503
Cover,
Ton
1
27.1
336718360
Screw
M6x12
2
60.2
330713501
Soillwav,
Fuel
Tank
1
27.2
330713567
Supporter,
Handle
Left
1
61
330713500
Fuel
Tank
Cap
1
27.3
330713524
Suooorter,
Rear
Cover
1
62
336718364
Screw
Msx20
4
28
330713525
CaoeNutMS
2
63
330728300
Air
Cleaner
Connector
1
29
330713527
Bolt
M6x16
2
64
333427005
Cover,
Left
1
30
336718362
Screw
Msx14
4
64.1
336718362
Screw
MSxl4
3
31
330713526
Protector
,Rear
Cover
1
64.2
330713566
Handle,
Left
1
32
336718361
Screw
M6x12
4
64.3
330713569
Cover,
Left
Side
1
33
333427002
Rio
ht
Cover
1
65
330713525
CaaeNutMS
6
33.1
336718362
Screw
Msx14
3
66
336718362
Screw
Msx14
4
33.2
330713546
Handle,
Riqht
1
67
330713527
Bolt
M6x16
2
33.3
333717002
So
ri
na
Leaf
5
68
330723533
Screw
MSxlO
1
33.4
330713549
Rubber
Seal
Sleeve
1
69
333427006
Maintenance
Window
1
33.5
336718359
Screw
St4.2x9.5
6 69.1
330713570
Screw
ST4.8x13
1
33.6
330713547
Cover,
Ria
ht
Muffler
1
69.2
330713571
Cover
Plate,
Left
1
33.7
330713545
Cover,
Ria
ht
Side
1
69.3
330713572
Maintenance
Window
1
34
330713525
Caae
Nut
MS
6
70
336718362
Screw
M5X14
6
35
330713527
Bolt
M6x16
2
71
336713835
Metal
Clamo
(08-014Jxb8
2
36
336718363
Screw
M6x20
4
72
357713591
LPG
hose
1
37
336718361
Screw
M6x12
8 73
333713525
CaaeNutMS
2
38
333427003
Handle
1
74
330713653
Front
Cover
1
English 39 Customer Service 1-844-FIRMAN1
background
Parts
Diagrams
-
Parts
Lists -
Wiring
Diagram
NO.
Part
Number
Description
Qty
NO.
Part
Number
Descriotion
Qty
75
330713657
Pull
Chock
Assembly
l
128
330713564
Suooorter,riqht
l
76
336718362
Screw
Msx14
4
129
330713565
Motor
Mount
4
77
330713527
Bolt
M6xl6
2
130
392428300
CO
Module
l
78
336755005
Circuit
Breaker
Cover
2
131
332717002
Washer
l
79
336713575
Receptacle Cover,S-20R Duplex
l
132
332717007
Bushinq
2
80
333717010
Screw
M3Xl0
l
133
332717003
Sten
ts,
Fue
I
Valve
l
81
330713613
Receptacle
Cover,
USB
l
134
330713574
Rectifier
l
82
330713602
Receptacle
Cover
2 135 330713651
Charaer
l
83
336718383
Screw
M4xl4
2
136
330713650
Control
Module
l
84
333457007
Table
l
137
330713582
Screw
M4xl4
5
85
330713618
Receptacle(
Battery
Charger)
l
138 336713561
Bolt
M6x2s
2
86
330713608
Receptacle
DC
12v
l
139
332457008
Ground
Wire
l
87
330713629
Switch
l
140
332457007
Inverter
l
88
330713603
Parallel
Ports
2
141
330713588
Base
Settinq
Component
l
89
336718345
Bolt
MSxl6
l
142
330713583
Plug.Wheel
2
90
336713577
Nut
MS
l 143
330713585
Washer¢12
2
91
333717011
Nut
MS
l
144
333727001
Wheel,
Ria
ht
l
92
336713579
Washer¢5
2 145
330713587
Axle
l
93
336713580
Washer¢5
l
146
333727002
Wheel,
Left
l
94
330713596
Nut
M4
6 147
336718302
Bolt
M6Xl2
4
95
336713588
Receptacle
5-20R
Duplex
l
148
330713563
Suooorter,Left
l
96
336713584
Receptacle
TT-30R
l
149
333717014
Nut
8
97
330713593
Receptacle
USB
l
150
330713589
Pluq
l
98
330713614 D.C lOA Breaker.push
Button
l
151
330713584
Retaina
Rina
¢12
2
99
330713594
A.C 20A Breaker.push
Button
l 152
333717015
Rubber
Mat
2
100
330713592
Control
Box
l
153
336718330
Bolt
M6x20
2
101
336713589
Screw
MSx38
2 154
330713623
Pinch,Rubbre
l
102
336713565
Screw
Msx14
l
155
330713622
Sheath.Battery
l
103
329713608
Washer¢5
l 156
332457009
Batterv(S.SAHl
l
104
333717012
Screw
Msx12
4 157 333717016
Screw
Msx14
3
105
330713659
Stents,
Fuel
Valve
l
158
330713620
Stents
l,batterv
l
106
330713655
Quick
Coupler
l 159
330713624
Stents
11,batterv
l
107
330713577
Fuel
Valve
l
160
333427008
Cushion
l
108
336718364
Screw
Msx20
2
161
357713571
Sheath,Connecter
Black
l
109
336713565
Screw
Msx14
2
162
332457010
Batterv
Wire(redl
l
110
330713595
Speed
Limiter
l
163 332457011
Batterv
Wire(blackl
l
lll
333717013
Nut
M3
5
164
336713540
Clio
(¢8X61
l
112
336713822
Micro
Switch
l
165
330713636
Vapor
Hose
2
l
113
333457010
Control
Panel
l
166
330713635
Vapor
Hose
l l
114
330713654
Lpg
Inlet
Cover
l
167
330713637
Carbon
Canister
l
115
336718383
Screw
M4xl4
2
168
330713638
Vaoor
Hose
3
l
116
330713660
Receptacle (
Battery
Charger)
l
169
332727005
Cover
l
117
330713656
Fuel
Valve
Knob
l
170
332717004
Screw
M4X5
2
118
336718383
Screw
M4xl4
l
171
330723533
Screw
MSxlQ
l
119
333718300
Lgnition
Switch
l
172
332717006
Screw
Msx14
2
120
330713599
Switch.economy
l
173
333718303
Flat
Washer
co6
2
121
330713606
Receptacle
Cover.DC
12V
l
174
333718302
sprinq
washer
ep6
2
122
336755002
Indicator
Light
l
175
333718301
Tooth
washer
2
123
336713574
Receptacle
Cover,TT-30R
l
176
333728300
Plastic
nut
l
124
333718304
Enqine
Switch
Cover
l
177
330713633
Batterv
Charae
Cable
l
125 333717013
Screw
Msx14
6
178
330713634
Batterv
Float
Charaer
l
126
336727009
Switch
Cover
l
179
332713647
LPG
Hose
With
Requlator
l
127 336718315
Nut
MS
12
English 40
Customer
Service 1-844-FIRMAN1
background
Parts
Diagrams
-
Parts
Lists
-
Wiring
Diagram
FIRMAN
193cc
Engine
NO.
Part
Number
Descri□tion
Otv
NO.
Part
Number
Descri□tion
IOtv
1
336713528
Bolt
M6x8
3
57
330723611
Gasket
Cvlinder
Head
1
2
330723528
Wire
Clio
2
58
330723548
Locatinq
Pins
2
3
330723526
Ro□e
Button
1
59
330723510
Lifter.Valve
2
4
330723525
Grio
Starter
1
60
330723553
Push
Rod
2
5
333467003
Guide
Plate
1
61
330723552
Guide
Plate.Push
Rod
1
6
330723524
Reciol
Starter
Cover
1
62
330723547
Valve
Exhaust
1
7
330723523
Recio
I
Starter
S
orina
1
63
330723554
Valve.Intake
1
8
333467004
Pull
Rooe
1
64
330723550
Oil
Seal.Valve
1
9
330723522
Reciol
Starter
Reel
1
65
330723559
SprinQ,Valve
2
10
330723521
Snrina
Ratchet
2
66
330723560
Retainer.Valve
Sorin
a 2
11
330723520
Patchet
Starter
2
67
330723561
Valve
Collet
2
12
330723519
Sarina
Ratchet
Guide
1
68
330723562
Bolt.Rocker
Arm
2
13
330723518
Pawl
Guide
1
69
330723563
Rocker
Arm
,Valve
2
14
330723517
Screw
Pawl
Guide
1
70
330723564
Adiustina
Nut.Valve
2
15
336718301
Bolt
M6x12
4
71
330723565
Lock
Nut
2
16
330723516
Fan
Cover
1
72
330723556
Stud
Bolt(M6x97)
2
17
330723515
Nut
M14
1
73
333476021
CvlinderHead
1
18
330723514
Pullev
Starter
1
74
330723555
Stud
BoltlM6x32l
2
19
330723513
Coolina
Fan
1
75
330723551
Bolt
M8x65
2
20
317718304
Bolt
M6x20
2
76
330723566
Air
Shroud,Cvlinder
1
21
330723537
l<lnition
Coil
1
77
330723001
Spark
Pluq
1
22
330723616
Flvwheel
1
78
333467006
Cylinder
Head
CoverGaske
1
23
330723501
Oil
Seal
2
79
330723568
'Cylinder
Head
Cover
Assembl\
1
24
330723615
Crankcase
1
80
333467007
Batte
rv
Ca
ble(-l
1
25
330723597
Relav,Starter
1
81
336718301
Bolt
M6X12 4
26
336723526
Bolt
M6x15
1
82
336713593
Bolt
M8x45
2
27
317718304
Bolt
M6x20
2
83
330723569
Breather
Tube
1
28
330723596
Starter
Motor
1
84
330723570
Gasket.Insulator
2
29
336713611
Sheath
2
85
330723571
I
nsu
lator,Carbu
re
tor
1
30
333467005
Connect
Wire
1
86
333467008
Carburetor
1
31
330723533
Screw
MSxlO
1
87
330723573
Gasket,
Air
Cleaner
1
32
336723604
Bolt&Seal
rinQ,
Drain
1
88
333467009
Air
Cleaner
1
33
330723506
BearinQ
6205
2
88.1
330723574
Base.Air
Cleaner
1
34
330723511
Locatina
Pins
2
88.2
333467010
Lock2
2
35
330723509
Woodruff
kev(4x6.5X16l
1
88.3
333467011
Lockl
2
36
330723534
Air
Guide
Board
1
88.4
330723576
Clapboard
1
37
330723533
Screw
Msx10
4
88.5
330723577
Sealina
Rina
1
38
330723508
Crankshaft
1
88.6
330723578
Element.Air
Cleaner
1
39
330723532
Camshafe
Como
1
88.7
330723579
Cover.Air
Cleaner
1
40
330723507
Gasket.Crankcase
Cover
1
89
336713517
NutM6
2
41
336718301
Bolt
M6x12
1
90
336713546
Screw
Msx10
1
42
330723505
Plate
Coil
1
91
357713569
Screw
Msx10
2
43
336718301
Bolt
M6x12
2
92
330723618
Support.Stepper
Motor
1
44
330723503
Oil
Level
Sensor
1
93
330723585
Clamp
Board.Choke
Control
Line
1
45
333467017
Sealina
Stria
2
94
357713569
Screw
Msx10
1
46
332467002
Cover
Crankcase
1
95
330723587
Steooer
Motor
Base
1
47
330723531
Oil
Diostick
Assemblv
1
96
330723588
Screw
M4x8
2
48
330723530
Oil
Nipple
1
97
330723589
Stepper
Motor
,Throttle
Valv,
1
49
357713584
Bolt
M8x35
6
98
380713542
Screw
M3x6
2
50
330723539
Connectina
Rod
1
99
330723591
Cover,Steooer
Motor
1
51
330723606
Piston
Pin
1
100
333467016
StartinQ
Cover
1
52
330723540
CircliP
2
101
333418300
Lid
Assembly
1
53
330723607
Piston
1
102
333418301
Piston
Rina
Assemblv
1
54
330723608
Rina
Coil
1
103
333467022
Cvlinder
Head
Asse
mblv
1
55
330723609
Rina
,Second
Piston
1
104
333467012
Gasket
Set
1
56
330723610
RinQ
First
Piston
1
105
336713579
Fl
at
Washer
CDS
1
English
41
Customer
Service 1-844-FIRMAN1
background
E
n,
...
en
n,
·-
a
en
C:
...
i
I
II)
....
II)
·-
..I
II)
....
...
n,
0.
I
II)
E
n,
...
en
n,
·-
a
II)
ill~
en
n,
·-
a
en
C:
...
i
[ALTERNATOR
BLQCK
-
.h
L I
I
"
o
i
i
"V
y
,i-
r------7
i
L
:llRI
!Elll
~
~
'
A I CONTROL I ECO.SW
ENGINE.SW
-
SUB
COIL
L _ - - J
MICRO
SWITCH
m
ENOINE
SWITCH
i
I
I UNIT
i
L
I .
STEPPER MOTOR
SPARKING
TCI UNIT OIL LEVB.
SW
L.,_,,_,,
__
P\.UG
G/Y
.:!!.
CONTROL BOX BLOCK
IB
RI
..!!.
G/Y
lw
IBIW
ENGINE
~LOC'SJ
GI
(Y
10
IG
I
DC1211
-~
~
==-~i
,,~
...
-·-1
~~--~
L IPGCUT
SOI.ENO~
J
REGULATOR
z
<(
::;
Q;
LL
.,.
..,.
"?
N
..,.
~
O>
c;
UJ
background
Service
-
Warranty
For
service
information
contact
FRI
MAN
customer
service
at
l-844-347-6261
or
at
www.firmanpowerequipment.com
to
obtain
warranty
service
information
or
to
order
re
placement
parts
or
accessories.
HOW
TO
ORDER
REPLACEMENT
PARTS
Even
quality-bui
It
equipment
such
as
this
electric
genera
tor
may
need
occa
siona
I
replacement
parts
to
maintain
it
in
good
condition
overt
he
years.
To
order
replacement
parts,
please
give
the
following
information,
e
Model
No.
Rev.
Level
and
Serial
No.
found
on
the
Data
Decal.
e
Parts
num
beror
numbers
as
shown
in
the
Parts
List
section.
A
brief
description
of
the
trouble
with
the
generator.
FIRMAN
4 Years
Limited
Warranty
Warranty
Qualifications
Register
your
product
using
the
QR
code
provided
or
at
www.firmanpowerequipment.com.
Fl
RMAN
wi
II
also
register
the
warranty
upon
receipt
of
your
Warranty
Registration
Card
and
a
copy
of
your
sales
receipt
from
one
of
FIRMAN's
retail
locations
as
proof
of
purchase.
Please
submit
your
warranty
registration
and
your
proof
of
purchase
with
in
ten(l0)
days
of
the
date
of
purchase.
Repair/Replacement
Warranty
FIRMAN
warrants
to
the
original
purchaser
that
the
mechanical
and
electrical
components
will
be
free
of
defects
in
material
and
workmanship
for
a
period
of
one
(1)
year(parts
and
labor)
and
4 years
(parts
and
technical
support)
from
the
original
date
of
purchase
90
days
[parts
and
labor]
and
180 days [parts]
for
commercial
&
industrial
use.
Transportation
charges
on
product
submitted
for
repair
or
replacement
under
this
warranty
are
the
sole
responsibility
of
the
purchaser.
This
warranty
only
applies
to
the
original
purchaser
and is
not
transferable.
Do
Not
Return
the
Unit
to
the
Place
of
Purchase
Contact
the
FIRMAN
customer
service
and
FIRMAN
will
troubleshoot
any
issue
via
phone
or
e-mail.
If
the
problem
is
not
corrected
by
this
method,
FIRMAN
will,
at
its
option,
authorize
evaluation,
repair
or
replacement
of
the
defective
part
or
component
at
a
FIRMAN
Service
Center.
Fl
RMAN
wi
II
provide
you
with
a
case
number
forwa
rranty
service.
Please
keep
it
for
future
reference.
Repairs
or
replacements
without
prior
authorization,
or
at
an
unauthorized
repair
facility,
wi
II
not
be
covered
by
this
warranty.
Warranty
Exclusions
This
warranty
does
not
cover
the
following
repairs
and
equipment.
Normal
Wear
Your
product
needs
periodic
parts
and
service
to
perform
well.
Th
is
warranty
does
not
cover
repair
when
normal
use
has
exhausted
the
life
ofa
part
or
the
equipment
as
a
whole.
English
43
Customer
Service: 1-844-FIRMAN1
background
Service
-
Warranty
Installation,
Use
and
Maintenance
This
warranty
will
not
apply
to
parts
and/or
labor
if
your
product
is
deemed
to
have
been
misused,
neglected,
involved
in
an
accident,
abused,
loaded
beyond
the
generator's
limits,
modified,
installed
improperly
or
connected
incorrectly
to
any
electrical
component.
Normal
maintenance
is
not
covered
by
this
warranty.
Other
Exclusions
Th
is
warranty
excludes,
-
cosmetic
defects
such
as
paint,
decals,
etc.
-wear
items
-
accessory
parts
-
failures
due
to
acts
of
God
and
other
force
majeure
events
beyond
the
manufacturer's
control
-
problems
caused
by
parts
that
are
not
original
FIRMAN
parts
-
units
used
for
prime
power
in
place
of
existing
utility
powerwhere
utility
is
present
or
in
place
of
utility
powerwhere
utility
power
service
does
not
normally
exist.
Limits
of
Implied
Warranty
and
Consequential
Damage
FIRMAN
disclaims
any
obligation
to
cover
any
loss
of
time,
use
of
this
product,
freight,
or
any
incidental
or
consequential
claim
by
anyone
from
using
this
product.
THIS
WARRANTY
IS
IN
LIEU
OF
ALL OTHER WARRANTIES, EXPRESS
OR
IMPLIED,
INCLUDING
WARRANTIES OF
MERCHANT
ABLILITY
OR FITNESS FOR A PARTICULAR PURPOSE.
Aun
it
provided
as
an
exchange
wi
II
be
subject
to
the
warranty
of
the
original
unit.
The
length
of
the
warranty
governing
the
exchanged
unit
will
remain
calculated
by
reference
to
the
purchase
date
of
the
original
unit.
This
warranty
gives
you
certain
legal
rights
which
may
change
from
state
to
state.
Your
state
may
also
have
other
rights
you
may
be
entitled
to
that
a re
not
listed
within
this
warranty.
Contact
Information
You
may
contact
FIRMAN
at:
Address
Firman
Power
Equipment
Inc.
Attn,
Customer
Service
8644
W.
Ludlow
Dr.
Peoria,
AZ
85381
www.firmanpowerequipment.com
We
are
FIRMAN
POWER
-And
we
are
here
for
you.
English 44
Customer
Service 1-844-FIRMAN1
background
Service
-
Warranty
FIRMAN
POWER
EQUIPMENT
INC.
Emission
Control
System
Warranty
CALIFORNIA
AND
FEDERAL EXHAUST
AND
EVAPORATIVE EMISSIONS CONTROL
WARRANTY
STATEMENT
YOUR WARRANTY RIGHTS
AND
OBLIGATIONS
The
California
Air
Resources Board, US Environmental Protection
Agency
("US EPA") and FIRMAN
POWER
EQUIPMENT
INC.(FIRMAN)
are
pleased
to
explain
the
emissions control
systems
warranty
on
your
2022-2023
or
later
Small Off-Road
Engine
("SORE") and
engine
powered equipment.
In
California, new equipment
that
use
small off-road engines
must
be
designed,
built
and
equipped
to
meet
the
State's
stringent
anti-smog
standards.
FIRMAN
must
warrant
the
emissions
control
systems on
your
SORE and engine powered equipment
for
the periods
of
time
listed below provided
there
has
been no abuse,
neglect
or
improper
maintenance
of
your
small off-road engine
or
equipment leading
to
the
failure
of
the
emissions control system.
Your
emissions
control
system
may
include
parts
such
as
the
carburetor
or
fuel-injection
system,
the
ignition
system
,
catalytic
converter,
fuel
tanks,
fuel
lines
(for
liquid
fuel
and
fuel
vapors),
fuel
caps,
valves,
canisters, filters,
clamps
and
other
associated
components.
Also
included
may
be
hoses,
belts,
connectors,
and
other
emission-related
assemblies.
Where
a
warrantable
condition
exists,
FIRMAN
will
repair
your
SORE
and
engine
powered
equipment
at
no
cost
to
you
including
diagnosis,
parts
and
labor
MANUFACTURER'S
WARRANTY
COVERAGE:
The exhaust and
evaporative
emissions
control
system
on
your
small
off-road
engine
and
engine
powered
equipment
is warrant
ed
for
two
years.
1f
any
emissions-related
part
on
your
small
off-road
engine
and
engine
powered
equipment
is
defec
t ive, t he
part
will
be
repaired
or
replaced
by
FJRMAN.
OWNER'S
WARRANTY
RESPONSIBILITIES:
As
the
SORE
and
engine
powered
equipment
own er,
you
are
responsible
for
the
perform
a nee
of
the
required
maintenance
listed
in
your
operator's
manual.
FIRMAN
recommends
that
you
retain
all receipts
cov
e
ring
m aintenan
c:e
on
your
SO
RE
and
engine
powered
equipment,
but
FIRMAN
cannot
deny
warranty
coverage
solely
fort
he
lack
of
receipts
orfor
your
failure
to
ensure
the
perform
a nee
of
a II
scheduled
maintenance.
As
the
SORE
and
engine
powered
equipment
owner,
you
should
however
be
aware
that
FIRMAN
may
deny
you
warrant y
coverage
if
your
small
off-road
engine
or
engine
powered
equipment
or
a
part
has fa
iled
due
to
abuse,
neglect,
or
improper
maintenance
or
unapproved
modifications.
You
are
responsible
for
presenting
your
small
off-road
engine
and
engine
powered
equipment
to
a FIRMAN dist
ribution
center
or
service
center
as
soon
as
th
e
problem
e)(ists. The
warranty
repairs shall
be
completed
in
a reasonable
amoun
t
of
time,
not
to
exceed
30 days.
If
you
have
any
questions
regarding
your
warranty
rights
and
responsibilities,
you
should
contact
FIRMAN
at
1-8
4
4-347-6261
.
FIRMAN Emission Control Defects
Warranty
Provisions
The warranty period begins
on
the
date t he
engine/equipment
is
delivered
to
an
ultimate
purchaser. FIRMAN warrants
to
th
e
ultimate
purchaser and each subsequent purchaser
that
the
engine is:
Designed,
built,
and
equipped
so
as
to
conform
with
all
applicable
r
egula
t
ions
adopted
by
the
Air
Resources Board and
US
EPA;
and
Free
from
defects
in
materials and
workmanship
th
at cause
the
failure
of
a
warranted
part
to
be
identical
in
all
material
respects
to
the
part
as
described
in
the
engine
manufacturers
application
for
certification.
The
warranty
on emissions-related parts is as follows:
{1)
Any
warranted
part
that
is
not
scheduled
for
replacement
as
required
maintenance
in
the
owner's
manual
supplied,
is
warranted
for
the
warranty
period
stated above.
Jf
any
such
part
fails
during
the
period
of
warranty
coverage,
the
part
will
be
repaired
or
replaced
by
FIRMAN
at
no
charge
to
the
owner.
Any
such
part
repaired
or
replaced
under
the
warranty
will
be
w
arranted
for
the
remaining
warr
a
nty
period.
{2)
Any
warranted
part
that
is sche
duled
only
for
regular
inspection
in
the
owner's
manual s
upplied,
is
warranted
for
the
war
ra
nty
period
stated above.
Any
such
part
repaired
or
replaced
under
warra
ntywill
be
warranted
fort
he
remaining
warranty
period.
{3)
Any
warrant
ed
part
that
is
scheduled
for
replacement
as
required
maintenanc
e
in
the
owner's
manual
supplied,
is
warranted
for
the
period
of
time
prior
to
the
first
scheduled
replacement
poin
t
for
that
part.
If
the
part
fails
prior
to
the
first
scheduled
replacement
,
the
part
will
be
repaired
or
replaced
by
FJRMAN
at
no
charge
to
the
owner.
Any
such
part
repaired
or
replaced
under
warranty
will
be
warranted
for
the
remainder
of
the
period
prior
to
the
first
scheduled
replacement
point
fort
he
pa
rt.
(4)
Repair
or
replacement
of
any
warranted
part
under
the
warranty
mu
st
be
perform
ed at
no
charge
to
the
owner
at
a
warranty
station.
(
S)
Notwithstanding
the
provisions
of
Subsection (4) above,
warranty
services
or
repairs
must
be
provided
by
FIRMAN t
hat
are franchised t o service
the
subject
engines.
(6)The
owner
must
not
be
charged
for
diagnos
t
ic
labor
t
hat
leads
to
the
determina
t
ion
that
a
warranted
part
is
in
fact
defective
,
provided
that
such
diagnostic
work
is
performed
at
a
warranty
station.
(7) FJRMAN is
liable
for
damages
to
other
engine
components
pro)(imately
caused
by
a
failure
under
warranty
of
any
warranted
part.
English 45
Customer
Service 1-844-FIRMAN1
background
Service
-
Warranty
(8)
Throughout
the
emissions
warranty
period
de
f
ined
in
Subsection (b)(2), FIRMAN
will
main
tain a
supply
of
warranted
parts
sufficient
to
meet
the
e)(pected
demand
for
such
parts.
(9)
Any
replacement
pa
rt
may
be
used
in
the
performa
nee
of
any
warranty
main
t enance
or
repairs and
must
be
provided
without
charge
to
the
owner.
Such
use
will
not
reduce
the
warranty
obligations
of
the
manufacturer.
(10)
Add-on
or
modified
parts
that
are
not
exempted
by
the
Air
Resources Board may
not
be used. The use
of
any
non-exempted
add-on
or
modified
parts
by
the
ultimate
purchaser
will
be
grounds
ford
isallowing a
warranty
claim.
The
manufac
t
urer
will
not
be
liable
to
warrant
failures
of
warranted
parts
caused
by
the
use
of
a non-e)(empted add -
on
or
modified
part.
PARTS
COVERED
BY
WARRANTY
Listed
below
are
the
parts
{if
equipped)
covered
by
the
Federal and California Emission
Control
System
Warranty,
1.lgnition
system
including:
- Spark plug
- I
gnition
coil
2. Fuel
metering
system:
- Fuel tank
- Fuel cap
-
fuel
lines
(for
liquid
fuel
and
fuel
vapors) and
related
fittings/damps
- Fuel
regulator,
carburetor
and
internal
parts.
3. Catalytic
muffler
assembly
including:
- Exhaust
manifold
-
Catalytic
conver
t er
-
Muffler
gasket
-pulse valve
Limitations
4.
Air
induction
system
including:
-
lnta
ke
pipe/manifold
-
Air
cleaner
5. Crankcase
breather
assembly
including:
- Bre
ather
connection
tu
be
6. Fuel
tank
evaporative
emission
control
system
including:
- Purge valves
- Carbon canist er
-
Vapor
hoses and
fitting/damps
This Emission
Control
System
Warranty
sha II
not
cover
any
of
the
following:
(a}
Consequential
damages such
as
loss
oftime,
inconvenience
, loss
of
use
of
the
engine
or
equipment,
etc.
(b) Diagnosis
and
inspection
fees
that
do
not
result
in
eligible
warranty
service
being
performed.
FIRMAN
POWER
EQUIPMENT
I
NC.
www.fi
rmanpowe
req u ip me
nt.com
English 46
Customer
Service 1-844-FIRMAN1
background
FOLLOW
US
ON
SOCIAL
MEDIA
USE
#EVERYGENERATORTELLSASTORY™
FOR
YOUR
CHANCE
TO
WIN
FIRMAN
SWAG
l!1
Ii
D
CJ
FIRMAN
POWER
EQUIPMENT
INC.
8644
W.
LUDLOW
DR
.
PEORIA
,
AZ
8S381
1-
844
-
347
- 6261
WWW.Fl
RMAN
POWE
REQUI P
MENT.COM
A
ll
1i9 h
l5
rese
r
ved.
An
y re
prin
t i
ng
or
u
na
u
tho
ri
zed
u5e
w i
th
out
th
e w
ri
tte
n p erm1
55io
n is
ex
p
rnss
ly p
ro
h ib
ited
.
P/ N:333748301 Re
v:00

Specifications

Firman WH03342 Questions and Answers