INSTALLATION
Locating Built-in Clearances
FIG. 03
Insulated jacket
If the grill is to be placed into a combustible enclosure, an approved insulated jacket is necessary.
Insulated jackets are available from your dealer. Use only the DCS by Fisher & Paykel insulated jacket
which has specifically been designed and tested for this purpose. Review the detail drawing shown
(Fig. 06) and take into account the provisions shown for gas line hook-up clearance in the right rear
corner. It is required that ventilation holes are provided in the enclosure to eliminate the potential
build-up of gas in the event of a gas leak. The supporting ledges or deck must be level and flat and
strong enough to support the grill and insulated jacket. The counter should also be level.
IMPORTANT!
Installing this product into a combustible enclosure without an insulated jacket could result in fire,
property damage and personal injury.
**DEFINITION OF COMBUSTIBLE MATERIAL - Any materials of a building structure or decorative
structure made of wood, compressed paper, plant fibers, vinyl/plastic or other materials that
are capable of transferring heat or being ignited and burned. Such material shall be considered
combustible even though flame-proofed, fire-retardant treated or surface-painted, or plastered.
IMPORTANT!
It is recommended that a minimum of two 311 x 311mm vents be provided in order to safely dissipate
unburned gas vapors in the event of a gas supply leak. These are to be located on each side of the
enclosure and within 127mm of the top.
Clearances to combustible construction**
Minimum of 450mm from the sides and rear of grill must be maintained to adjacent vertical
combustible construction, above the counter top level. Intense heat, and large volumes of smoke will
exhaust from the rear of the grill (Fig. 01b). This may discolor or damage unprotected areas. Do not
install under unprotected combustible construction without using a fire safe ventilation system.
A 450mm minimum clearance must be maintained under the counter top to combustible
construction. The clearance can be modified by a use of an insulated jacket.
PRODUCT DIMENSIONS MM
A
Minimum distance from combustible surface to grill
450
b
Minimum distance from combustible surface to grill at rear
310
NON-COMBUSTIBLE
SURFACE
=
COMBUSTIBLE
SURFACE
=
A
A b