RIGOL Chapter 11 Waveform Record
11-2 MSO2000A/DS2000A Users Guide
Waveform Record
When the waveform record function is turned on, waveforms from all the channels
currently turned on will be recorded. Press Utility Record Mode and use
to select Record to open the waveform record operation menu.
1. End Frame
Press End Frame and use or the navigation knob to set the desired number
of frames to be recorded. The available range is from 1 to the maximum number
of frames that can be recorded currently (displayed in Total Frames).
2. Record Operation
Waveform recod can be realized via the menu or the shortcut buttons at the
front panel.
Menu Front Panel
Press Operate and select
to start recoding.
Press
; the backlight goes on (in red)
and starts to flash, indicating that the
record is started.
When the record is finished,
changes to
automatically. You can also
select manually.
When the record is finished,
goes off
automatically and
goes on (in
orange). You can also press
dir ect ly.
3. I nterval
Set the time interval between the frames in waveform record and the range
available is from 100 ns to 10 s.
4. Total Frames
The menu shows the maximum number of frames that can be recorded
currently.
The number of points of each frame is the current memory depth
[1]
. As the
capacity of the waveform memory is fixed, the more the number of points each
frame of waveform has, the less the number of waveform frames can be
recorded. Thus, the maximum end frame of waveform record is decided by the
memory depth currently selected. Please refer to the instruction in Memory
Depth to select the desired memory depth.