Chapter 6 MATH and Measurements RIGOL
MSO2000A/DS2000A User’s Guide 6-17
Voltage Parameters
Figure 6-5 Voltage Parameters
1. Vmax: the voltage value from the highest point of the waveform to the GND.
2. Vmin: the voltage value from the lowest point of the waveform to the GND.
3. Vpp: the voltage value from the highest point to the lowest point of the
waveform.
4. Vtop: the voltage value from the flat top of the waveform to the GND.
5. Vbase: the voltage value from the flat base of the waveform to the GND.
6. Vamp: the voltage value from the top of the waveform to the base of the
waveform.
7. Vavg: the arithmetic average value on the whole waveform or on the gating
area. The calculation formula is as shown below.
i
x
Average
n
=
∑
, wherein,
i
x
is the
i
th point being measured,
n
is the
number of points being measured.
8. Vrms-N: the root mean square value on the whole waveform or the gating area.
The calculation formula is as shown below.
9. Vrms-1: the root mean square value within a period. The calculation formula is
as follows.
2
1
n
i
i
x
RMS
n
=
=
∑
, wherein,
i
x
is the
i
th point being measured,
n
is the number
of points being measured.
Preshoot
Vamp
Vbase
Vmax
Vmin
Vpp
Vtop
Overshoot