Add Original Data on Stream
Add and save original raw data to stream. The function requires higher network
bandwidth.
Data Refresh Interval
It means the refresh interval of original data.
Display Pixel-to-Pixel Thermometry Data on Stream
Add and save real-time pixel-to-pixel thermometry data to stream. The function
requires higher network bandwidth.
The function varies according to different camera models.
Pixel-to-Pixel Thermometry Data Refresh Interval
It means the refresh interval of thermometry data.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin
(K).
Temperature Range
Select the temperature measurement range. The device can adjust the temperature
range automatically if you select Auto.
Atmospheric Temperature
Set the atmospheric temperature.
Atmospheric Humidity
Set the atmospheric humidity.
Atmospheric Transmissivity
Set the atmospheric transmissivity from 0 to 1.
Distance Mode
Select the distance mode for temperature measurement. Fixed Distance and Self-
Adaption are selectable.
Version
View the version of current algorithm.
Calibration File Version
View the version of calibration î´ªle.
Alarm Interval
Set the alarm interval between two alarms.
Reî´«ect Light Filter
Enable these functions if there is strong reî´«ected light from sun, or it may cause false
alarm. The î´ªlter sensitivity can be adjusted.