Check Display Filtering Status, and the OSD will be displayed when the function is
enabled.
Click Restart to restart the algorithm library of reî´«ect light î´ªlter.
The Reî´«ect Light Filter function varies according to different camera models.
Forklift Filter
Enable these functions if there is forklift in the scene, or it may cause false alarm. The
î´ªlter level can be adjusted.
Check Display Filtering Status, and an OSD will be displayed when the function is
enabled.
Set Filtering Temperature, e.g., set the ltering temperature as 300 °C and forklifts
can be ltered only when their temperature is lower than 300 °C. The function varies
according to different camera models.
Click Restart to restart algorithm library of forklift î´ªlter.
Note
Forklift Filter is mutually exclusive with VCA, Ship Detection and Fire and Smoke
Detection.
4.
Click Save.
3.3.2 Set Normal Mode
This function is used to measure the temperature of the whole scene and alarm.
Steps
1.
Check Enable Temperature Measurement.
2.
Refer to
Set Thermography Parameters
to set the parameters.
3.
Go to Conî´ªguration > Temperature Measurement & Fire Prevention > Advanced
Settings , and select Normal.
4.
Conî´ªgure the parameters of normal mode.
Emissivity
Set the emissivity of your target. The emissivity of each object is different.
Distance
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshold, and this status
keeps more than
Filtering Time, it triggers pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps
more than Filtering Time, it triggers alarm.