Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/19096672-ds-7716ni-i4-16pb/bg52.png)
Steps
1. Go to Conguraon → VCA → Object Thrown from Building via web browser.
2. Select a camera.
3. Check Enable Object Thrown from Building.
4. Click Area Sengs and click to draw rule area.
Note
a. Click to start drawing, le click each me on the screen to determine a vertex, right click
to stop drawing. The inside of the drawn polygon is the shielded area. If you make a mistake,
you can click and redraw.
b. It is recommended to draw the detecon area according to the outline of the building in the
screen.
5. Enter Rule Name. The default name is rule 1.
6. Set the detecon parameters.
Sensivity
Used to detect and lter object(s) that are denitely not thrown from the building. The higher
the value, the greater the possibility of a false alarm. Default value of 50 is recommended.
Detecon Condence
Used to detect suspicious object(s) in the detecon area. The lower the value, the easier it is
to detect the object in the video and make a judgment. Default value of 50 is recommended.
Target Condence
Used to determine if the target is a real object thrown from building. The lower the value, the
easier it is for a detected object in the video to be determined as an object thrown from
building, and the greater the likelihood of a false alarm. Default value of 50 is recommended.
Note
Default value is recommended at rst. Adjustment can be made if false alarm is triggered
frequently during the operaon. Target condence is recommended to be adjusted inially, and
detecon condence is recommended to be adjusted later if no sound detecon results
provided. If sll, there is no obvious eect, then adjust the sensivity.
7. Click Save.
8. Click Arming Schedule. Refer to Congure Arming Schedule .
9. Click Linkage Method. Refer to Congure Linkage Acons .
10. Congure Shield Region.
1)Click Shield Region.
2)Draw the region.