Adjust Sensivity during Patrol. The bigger the value is, the more easily the re source can
be detected, and the false rate is higher.
by Mulple Frame
The system stops to check the doubul re source aer rst detecon. It alarms with high
accuracy aer double checking the re source on mulple frames, thus the detecon speed
is slow.
As to the detecon sensivity of this mode, adjust the Sensivity during Patrol for the rst
detecon and Vericaon Sensivity for the double check.
In this detecon mode, Smoke Auxiliary Detecon can also be used to help verify the re
source.
Check Cancel Repeated Alarm and the device alarms only one me if re source detected in
the same place during one day.
Smoke Auxiliary Detecon
The device conducts smoke detecon to verify the re source. It can be congured when the
detecon mode is selected as by Mulple Frame.
Cancel Repeated Alarm
Alarm only one me if re source detected in the same place. It can be congured when the
detecon mode is selected as by Mulple Frame.
Sensivity
The sensivity of re detecon. The bigger the value is, more easily the re source can be
detected, and the false rate is higher.
Hold-and-Alarm Mode
Auto and Manual are selectable. The system will stop when it detects the re source. You can
set the duraon while it keeps sll.
Auto
You can set the dwell me. During the dwell me the camera stays sll where it detects the
re source when performing auto scan, patrol, paern, scheduled task, and park acon.
Manual
The device stays sll where it detects the re source, unl you manually
Fire Source Zoom Rao
Auto
The opcal channel changes its zoom rao unl the thermal channel has the same eld of
view.
Manual
You can set the opcal zoom rao.