7. Click Apply.
Video Loss
Detect video loss of a camera and take alarm response acons.
Steps
1. Go to Conguraon → Event → Normal Event → Video Loss .
2. Set Camera.
3. Turn on Enable.
4. Set the arming schedule. Refer to Congure Arming Schedule for details.
5. Set the linkage acons. Refer to Congure Alarm Linkage Acon for details.
6. Click Apply.
Alarm Input
Set linkage acons for an external sensor alarm.
Steps
1. Go to Conguraon → Event → Normal Event → Alarm Input .
Figure 6-17 Alarm Input
Note
Local alarm input: Local alarm input is triggered by the external device that connected to the
video recorder's terminal block.
2. Click of a desired alarm input.
Figure 6-18 Edit Alarm Input
3. Customize Alarm Name.
4. Set alarm type as N.O (normally open) or N.C (normally closed).
5. Set Sengs as Input to enable the funcon.
Note
If you set Sengs as Nonuse, the alarm input will be disabled. If you set Sengs as One-Key
Disarming, the selected linkage method(s) of the alarm input will be disabled.