15” TRUE ICE
®
MACHINE INSTALL GUIDE
TEC_TM_155 | REV. D | EN 09/23/2022
Page 39 of 66
CABINET OPERATION
ELECTRONIC DISPLAY CODES
Display Definition Detailed Description
Clean cycle reminder
In Menu Mode: view the number days elapsed since the
automatic clean cycle was performed
Drain pump failure
Clogged or kinked drain line. Drain was not able to clear
within 5 minutes of running.
Thermistor 1 Failure
Thermistor 1 is located on the evaporator outlet tube
and is used for terminating the harvest. E1 means the
probe has a bad or loose connection.
Thermistor 2 Failure
Thermistor 2 is located on the condenser outlet tube
and is used for fan cycling. E2 means the probe has a
bad or loose connection.
Fill mode
Water fills the reservoir for 2-3 minutes
Condenser coil cleaning reminder
In Menu Mode: view the number of days elapsed since
the last condenser coil cleaning.
Freeze time
In Menu Mode: view the most recent freeze times in
minutes. View history of five previous cycles:
-1 (most recent), -2, -3, -4, -5
Ice storage bin is full
Ice has reached the full level and the unit is in standby
.
Water level sensor
In Menu Mode: h1 is the water level reading inside the
sump tank read in mm of H
2
O.
Ice level sensor
In Menu Mode: h2 is the ice level reading inside the ice
storage bin in cm.
Full = 35.0 and Empty = 55.0
Harvesting ice
Ice cubes drop in the storage bin and water fills the
reservoir for the next batch of ice.
Harvest time
In Menu Mode: view the most recent harvest times in
minutes. View history of five previous cycles
-1 (most recent), -2, -3, -4, -5
Making ice
Circulation pump is running, machine sprays water into
the molds to make cubes.
High Pressure sensor
In Menu Mode: P1 is the high side pressure transducer
taken at the compressor discharge read in PSI (lb/in
2
)
Low Pressure sensor
In Menu Mode: P2 is the low side pressure transducer
taken at the compressor suction read in PSI (lb/in
2
)
Water filter reminder
In Menu Mode: view the number of days elapsed since
the last water filter replacement
Evaporator temperature
In Menu Mode: t1 is the evaporator outlet temperature
read in degrees Fahrenheit
Condenser temperature
In Menu Mode: t2 is the condenser outlet temperature
read in degrees Fahrenheit