15” TRUE ICE
®
MACHINE INSTALL GUIDE
TEC_TM_155 | REV. D | EN 09/23/2022
Page 37 of 66
CABINET OPERATION
ICE MAKING SEQUENCE
Your TRUE Ice
®
machine will produce one batch of
ice (24 cubes) approximately every 20 minutes. The
following steps occur during ice making
INITIAL FILL / INITIAL HARVEST
The ice machine always begins in Fill mode.
During Fill or Harvest modes
The display will read FiL (Fill mode) or hAr
(Harvest mode).
The reservoir fills with water (for 2–3 minutes)
Excess / residual water drains.
Any residual ice cubes from a previous cycle are
melted free from the evaporator by warming the
evaporator with a warm refrigerant (Harvest mode).
ICE MAKING
When making ice
The display will read ICE
Water sprays into the inverted ice cups as the
evaporator cools, forming ultra-clear ice cubes in
each cup
The compressor, condenser fan motor, and water
pump operate.
As ice is produced on the evaporator, the reservoir's
water level will lower.
Adjusting the ice cube size alters the water level
needed for completing the cycle.
The ice making cycle ends when
The reservoir's water level has dropped to a
sufficient level based on the ice cube size
setting OR
When the t1 evaporator probe detects the
minimum temperature threshold.
ICE HARVEST
When harvesting ice
The display will read hAr
The compressor remains on, but the condenser fan
motor and pump turn off. The hot gas bypass and
water valves open.
As the evaporator warms, ice cubes begin to fall
into the ice bin.
The reservoir refills with water and overflows to
flush impurities down to the drain pump.
The harvest cycle ends when the evaporator
reaches 47˚F (8.3˚C) and then a completion
timer expires.
All 24 ice cubes should fall into the ice storage bin
before the next ice making cycle begins.
FULL BIN
When the ice bin is full–
The display will read FUL
The ice machine shuts off automatically when the
ice level sensor determines the amount of ice has
reached the set level (see "Adjust Ice Level",
page 39).
The condenser fan will turn on in reverse to clean
the condenser; this removes any built-up dust or
debris, which prolongs the time needed between
full condenser coil cleanings.
The drain pump will periodically run to remove any
residual water in the bin from melted ice cubes.
The ice machine turns back on when the ice level
sensor determines the amount of ice has decreased
to below the set level (see "Adjust Ice Level",
page 39).