8
ENG
Nozzle change operation
Ventilation of room
Reduced gas flow rate setting for hob taps
1. Please use driver with special head for removed and install nozzle as. (figure 3)
2. Please remove nozzle (figure 4) from burner with special nozzle driver and install new nozzle. (figure 5)
1. Ignite the burner that is to be adjustment and turn the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjustment screw. For LPG (butane-pro pane)
turn the screw clockwise. For the naturel gas, you should turn the screw counter- clockwise once. “The normal
length of a straight flame in the reduced position should be 6-7 mm.
4. If the flame is higher then the desired position, turn the screw clockwise. If it is smaller turn anticolockwise.
5. For the last control, bring the burner both to higt-flame and reduced positions and check whether the flame is
on or off. Depending on the type of gas tap used in your appliance the adjustment screw position may vary. To
adjust your oven acc. to the gas type, make the adjustment for reduced flame carefully by turning with a small
screwdriver as shown below on the screw in the middle of the gas cocks as well as nozzle changes. (figure 6
and 7)
Figure 3 Figure 4 Figure 5
The air needed for burning is received from room air and the gases emitted are given directly in room. For safe
operation of your product, good room ventilation is a precondition. If no window or room to be utilized for room
ventilation is available, additional ventilation should be installed. However, room has a door opening outside, it is
no needed to vent holes.
Room size Ventilating opening
Smaller than 5 m³ min. 100 cm²
Between 5 m³ - 10 m³ min. 50 cm²
Bigger than 10 m³ no need
In basement or cellar min. 65 cm²
Figure 6 Figure 7