ILve PWI60MP 60cm Freestanding Electric Oven/Stove

Operating & Installation Manual - Page 43

For PWI60MP.

PDF File Manual, 64 pages, Read Online | Download pdf file

PWI60MP photo
Loading ...
Loading ...
Loading ...
Low Flame Adjustment of Burners
When installing the appliance it is recommended to check that the burner minimum speed (Low Flame
Setting) has been correctly adjusted. If it is necessary to change the type of gas, adjustment of the low
flame setting must be completed by the installer. To adjust the minimum setting for the burners the
following steps must be completed
Minimum flow of valve cooking hob taps
Switch on the burner and turn the control knob towards the minimum flow position;
Remove the knob;
Using a screwdriver, adjust the internal screw until the correct low flame is obtained, the screw is
located just to the right of the shaft see figure 1
Refit the knob.
Minimum flow of non-valved cooking hob taps
•Switchontheburnerandturnthecontrolknobtowardstheminimumflowposition;
•Removetheknob;
•Insertasmallscrewdriverintotheshaftofthegasvalveandadjusttheinternalscrewuntilthecorrect
low flame is obtained; see figure 2
•Refittheknob.
•Unscrewtheadjustmentscrewtoincreasetheflow,ortightenittoreducetheflow.
•Theadjustmentiscorrectwhenthelowflamemeasuresapproximately3or4mm.
•ForULPGtheadjustmentscrewshouldbeturnedfullyclockwise.
•Makesuretheflamedoesnotgooutwhenchangingquicklyfrommaximumflowandviceversa.
ENSURE THE MINIMUM FLAME WILL NOT BE EXTINGUISHED BY AIR DRAUGHTS
43ILVE Freestanding Operating Manual
Loading ...
Loading ...
Loading ...