MAINTENANCE SCHEDULE
Inspect for Clean Replace Replace
Maintenance Damage Before Every Every 25 Hours Every
Part Each Use 5 Hours or Yearly 50 Hours
* CATALYTIC MUFFLER ASSEMBLY ....................................................................................X
SPARK SCREEN ..................................................................................................................X
* AIR FILTER ASSY
includes:
Filter..................................................................... X
* CARBURETOR ASSY
includes:
Gaskets ...............................X
* FUEL TANK ASSY
includes:
Fuel Lines ............................X
Fuel Cap ..............................X
Fuel Filter ............................................................................................. X
* IGNITION ASSY
includes:
Spark Plug ........................................................................................... X
* NOTICE: THE USE OF EMISSION CONTROL COMPONENTS OTHER THAN THOSE DESIGNED
FOR THIS UNIT IS A VIOLATION OF FEDERAL LAW.
Chain specifications: 3/8 in. pitch, .050 in. chain gauge, low-profile skip tooth
Length of Bar Guide Bar Part Number Chain Part Number Drive Links
14 in. 311752001 Power Care Y52 52
16 in. 311752002 Power Care Y56 56
BAR AND CHAIN COMBINATIONS
MAINTENANCE
Run the engine until it stops. This will remove
all fuel-lubricant mix that could become stale
and leave varnish and gum in the fuel system.
Squeeze primer bulb several times to purge fuel
from carburetor.
Drain all bar and chain lubricant from tank into
a container approved for lubricant.
Clean all foreign material from the saw.
Store it in a well-ventilated place that is inac-
cessible to children.
NOTE: Keep away from corrosive agents such
as garden chemicals and de-icing salts.
Abide by all federal and local regulations for the
safe storage and handling of gasoline. Excess fuel
should be used in other 2-cycle engine powered
equipment.
HIGH ALTITUDE ENGINE OPERATION
Your engine is configured for operation below 2000
feet altitude at the factory. Your engine must be
reconfigured for operation above 2000 feet alti-
tude. Operating the engine with the wrong engine
configuration at a given altitude may increase its
emissions, decrease fuel efficiency, degrade per-
formance, and cause irreversible damage. Engines
configured for high altitude operation cannot be
operated in standard altitude conditions. A qualified
service center should ensure that your engine is
properly configured for your location.