Siglent SPS5043X 40V/90A/1080W Single Channel Switch Mode Power Supply

Manual - Page 88

For SPS5043X.

PDF File Manual, 106 pages, Read Online | Download pdf file

SPS5043X photo
Loading ...
Loading ...
Loading ...
SPS5000X Series User Manual
WWW.SIGLENT.COM 87
Description: Set the voltage response of CH1 channel to FAST (fast priority) (set to
CV mode available)
Command format: [:SOURce]:VOLTage[:RESPonse]:MODE? <channel>
Description: Get the voltage response change mode of the selected channel
E.g: :SOURce:VOLTage:RESPonse:MODE? CH1
Response: Slope priority\n
Set current response change mode
Command format: [:SOURce]:CURRent [:RESPonse]:MODE <channel>,{FAST| SLOPE}
Description: Set the current response change mode of the selected channel (FAST /
SLOPE)
E.g: :SOURce:CURRent:RESPonse:MODE CH1,FAST
Description: Set the current response of CH1 channel to FAST (fast priority) (available
when set to CC mode)
Command format: [:SOURce]:CURRent [:RESPonse]:MODE? <channel>
Description: Get the current response change mode of the selected channel
E.g: :SOURce:CURRent:RESPonse:MODE? CH1
Response: Fast priority\n
Set voltage control mode
Command format: [:SOURce]:CTRL:VOLTage:MODE <channel>,{LOCAL| EXT_V | EXT_R | EXT_R_MAX }
Description: Set the voltage control mode of the selected channel (LOCAL| EXT_V |
EXT_R | EXT_R_MAX)
E.g: :SOURce:CTRL:VOLTage:MODE CH1,LOCAL
Description: Set the CH1 channel voltage control mode to LOCAL mode
Command format: [:SOURce]:CTRL:VOLTage:MODE? <channel>
Description: Get the voltage control mode of the selected channel
E.g: :SOURce:CTRL:VOLTage:MODE? CH1
Response: LOCAL\n
Set current control mode
Command format: [:SOURce]:CTRL:CURRage:MODE <channel>,{LOCAL| EXT_V | EXT_R | EXT_R_MAX }
Loading ...