Siglent SPS5043X 40V/90A/1080W Single Channel Switch Mode Power Supply

Manual - Page 55

For SPS5043X.

PDF File Manual, 106 pages, Read Online | Download pdf file

SPS5043X photo
Loading ...
Loading ...
Loading ...
SPS5000X Series User Manual
WWW.SIGLENT.COM 54
In parallel, host A realizes the output control of the entire parallel system. The maximum
output current that can be set is twice the rated current of the current model. Host A sets
the output voltage and current to the output voltage and current of the parallel system.
(3) ABC parallel
Three SPSs of the same model are arbitrarily named A, B and C.
Mode setting
Setting method: Menu 1.System M/S mode settings enter the setting
interface, press the knob to display a cursor, turn the knob to select the configuration of
the slave/slave mode, and press the knob to make the setting effective. When * appears
in front of the option, it means the currently selected item.
After power supply A enters the menu 5. M/S mode settings interface according to the
above setting method, select 3.Master/ Parallel2 option, power supply B enters the
setting interface according to the above method, select 5. Slave/ Parallel option, power
supply C and B have the same settings, also select 5. Slave/ Parallel option.
Setting interface