9
When used normally, and when observing
the instructions, lead-acid batteries do not
pose any risk.
However, keep in mind that lead-acid bat-
teries contain sulphuric acid which can
cause chemical burns and corrosion.
If there is spillage or, if the battery is
leaking, acid is escaping, lay down a
binding agent such as sand. Do not let
it reach the sewer system, soil or a body
of water.
Neutralise the acid with lime/baking
soda and dispose of it according to local
regulations.
Contact a waste management compa-
ny to dispose of faulty batteries.
Rinse thoroughly with lots of clear water
if acid gets into the eye or comes in con-
tact with the skin.
Then consult a doctor immediately.
Wash off the acid If it comes in contact
with the clothes.
Change clothing.
Warning
Regularly check the fluid level in acid-filled
batteries.
The acid in a fully charged battery has a
specific weight of 1.28 kg/l at a temper-
ature of 20 °C.
The acid in a partially discharged bat-
tery has a specific weight between 1.00
and 1.28 kg/l.
The specific weight of the acid must be
uniform in all cells.
Unscrew all cell caps.
Take a sample from each cell using the
acid tester.
Put the acid sample back into the same
cell.
Where fluid level is too low, top up cells
to the mark provided with distilled wa-
ter.
Charge battery.
Screw in cell caps.
We recommend the use of our batteries
and chargers; only then a claim under war-
ranty exists.
NOTICE
With the KM 105/100 R Bp Pack, the KM
105/110 R Bp Pack and the KM 125/130 R
Bp Pack low-maintenance batteries and
the charger are already installed.
ATTENTION
Only if you use the batteries and chargers
recommended by Kärcher, a claim under
warranty exists.
KM 105/100 R / KM 105/ 110 R Bp .
125/130 R Bp
Note
When using batteries of other manufactur-
ers, the maximum battery dimensions must
be observed.
KM 105/100 R Bp
KM 105/110 R Bp
The device requires 4 single batteries with
6 volt each or a battery trough.
The available space (LxWxH) in the device
is: 622 mm x 402 mm x 379 mm
KM 125/130 R Bp
The available space (LxWxH) in the device
is:827 mm x 324 mm x 462 mm
Please follow these instructions if you are
using low-maintenance batteries:
It is necessary to conform to the maxi-
mum battery dimensions.
When charging low-maintenance bat-
teries, the left cover must be opened.
While charging maintenance-free bat-
teries, follow the specifications of the
battery manufacturer.
Open left cover.
Remove the appliance cover.
Insert batteries into the battery mount.
Warning
Pay attention to correct poles.
Connect pole terminal (red cable) to
positive pole (+).
Screw the connection lines onto the
batteries.
Connect pole terminal to negative pole
(-).
NOTICE
When removing the battery, make sure that
the negative pole lead is disconnected first.
Check that the battery pole and pole termi-
nals are adequately protected with pole
grease.
NOTICE
Charge the batteries before commissioning
the appliance.
DANGER
Risk of injury!
Comply with safety regulations on the
handling of batteries. Observe the di-
rections provided by the manufacturer
of the charger.
DANGER
Risk of injury!
Only put the charger into operation if
the mains connection is free of damage.
A damaged mains connection must im-
mediately be replaced by the manufac-
turer, the customer service or a quali-
fied person.
DANGER
Risk of injury!
Charge the battery only with an appro-
priate charger.
NOTICE
The charger is controlled electronically and
completes the charging process automati-
cally. All functions of the device are auto-
matically interrupted during the charging
process.
NOTICE
Procedures in the event of unintentional
release of battery acid
Check and correct the fluid level of
the battery (only for low-
maintenance batteries)
Recommended batteries, chargers
Order No.
Volume [m
3
} *
Air flow [m
3
/h] **
400 Ah - Trogbat-
terie
6.654-
156.0
33,0 13,20
240 Ah - Trogbat-
terie
6.654-
112.0
19,8 07,92
240 Ah - Einzelbat-
terie 6V
6.654-
119.0
5,12 2,05
180 Ah - Einzelbat-
terie 6V
6.654-
124.0
3,8 1,52
* Minimum volume of the battery charging
room
** Minimum air flow between the battery
charging room and the surroundings
Use of batteries and chargers of other
manufacturers
Battery Battery set Charger
240 Ah - Trog-
batterie (nass)
6.654-112.0 4.654-003.0
180 Ah - Einzel-
batterie (Gel)
6.654-124.0 4.654-022.0
240 Ah - Einzel-
batterie (Gel)
6.654-119.0 4.654-023.0
Battery Battery set Charger
400 Ah - Trog-
batterie (nass)
6.654-156.0 6.654-327.0
240 Ah - Trog-
batterie (nass)
6.654-112.0 6.654-325.0
240 Ah - Einzel-
batterie (Gel)
6.654-119.0 6.654-326.0
Maximum battery dimensions (single
battery)
Installing and connecting the
batteries
Charging battery
34 EN
Loading ...
Loading ...
Loading ...