Cobra CB6-B 600mm Gas Barbecue Bench Model

Installation Operation Manual - Page 6

For CB6-B.

PDF File Manual, 21 pages, Read Online | Download pdf file

CB6-B photo
Loading ...
Loading ...
Loading ...
4
- All Other Markets:
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at 'High Flame'
setting.
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be adjusted, apart from
when converting between gasses, if required.
(**) TOWN GAS Only - Burner operating pressure is to be adjusted using the adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications section of this manual for further details.
Gas supply connection point is located at the rear of the appliance:-
For CB6 - Approximately 215mm from the left hand side and 535mm from the floor and is entered from
beneath the appliance.
Gas Connection is ½BSPT male.
For CB9 - Approximately 215mm from the left hand side and 555mm from the floor and is entered from
beneath the appliance.
Gas Connection is ¾BSPT male.
LP Gas (Propane) LP Gas (Butane)
CB6 CB9 CB6 CB9
Input Rating
66.0 MJ/hr 100.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr
Supply Pressure
2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.60 kPa 2.60 kPa
Gas Connection
½" BSPT Male ¾" BSPT Male ½" BSPT Male ¾" BSPT Male
Town Gas (**)
CB6 CB9 CB6 CB9
Input Rating 66.0 MJ/hr 100.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa 0.63 kPa
Gas Connection
½" BSPT Male ¾" BSPT Male ½" BSPT Male ¾" BSPT Male
Loading ...
Loading ...
Loading ...