17
- All Other Markets:
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at 'High Flame'
setting.
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be adjusted, apart from
when converting between gasses, if required.
(**) TOWN GAS Only - Burner operating pressure is to be adjusted using the adjustable gas regulator
supplied.
Refer to the ‘Gas Conversion and Specifications section of this manual for further details.
Main Burner Injectors
2.70mm 4.50mm
Pilot Burner Injectors
0.45 0.75
Low Fire Adjustment
1
1
/
4
turns out (ccw) 2 turns out (ccw)
Burner Operating Pressure (*)
0.95 kPa 0.63 kPa
Main Burner Aeration Shutter
Fully Open Fully Open
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure
specified)
Main Burner Injectors
1.65mm 1.55mm
Pilot Burner Injectors
0.30 0.30
Low Fire Adjustment
½ turn out (ccw) ½ turn out (ccw)
Burner Operating Pressure (*)
2.6 kPa 2.6 kPa
Main Burner Aeration Shutter
Fully Open Fully Open
Gas Regulator Cap Screw
Loading ...