Cobra CB6-B 600mm Gas Barbecue Bench Model

Installation Operation Manual - Page 18

For CB6-B.

PDF File Manual, 21 pages, Read Online | Download pdf file

CB6-B photo
Loading ...
Loading ...
Loading ...
16
- Australia:
- New Zealand:
- United Kingdom:
Category: II
2H3P
(20, 30 / 37).
Flue Type: A
1.
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set and not to be adjusted, apart from when converting between gases,
if required. (Refer to details in this section for further information.
Main Burner Injectors
2.70mm 1.65mm
Pilot Burner Injectors
0.45 0.30
Low Fire Adjustment
1
1
/
4
turns out (ccw) ½ turn out (ccw)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Main Burner Aeration Shutter
Fully Open Fully Open
Gas Regulator Cap Screw
Main Burner Injectors
2.70 mm 1.65 mm
Pilot Burner Injectors
0.45 0.30
Low Fire Adjustment
1
1
/
4
turns out (ccw) ½ turn out (ccw)
Supply Pressure
20 mbar 30 / 37 mbar
Burner Operating Pressure (*)
10 mbar 26 mbar
Main Burner Aeration Shutter
Fully Open Fully Open
Gas Regulator Cap Screw
Main Burner Injectors
2.70mm 1.65mm
Pilot Burner Injectors
0.45 0.30
Low Fire Adjustment
1
1
/
4
turns out (ccw) ½ turn out (ccw)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Main Burner Aeration Shutter
Fully Open Fully Open
Gas Regulator Cap Screw