Cobra CB6-B 600mm Gas Barbecue Bench Model

Installation Operation Manual - Page 5

For CB6-B.

PDF File Manual, 21 pages, Read Online | Download pdf file

CB6-B photo
Loading ...
Loading ...
Loading ...
3
Model Covered in this Specification -
A commercial heavy duty, fully modular, gas fired barbeque created for modular kitchens supplied in either
600mm or 900mm wide options. The barbeque is fitted with branding grates and aluminised steel burners,
with individual ‘Hi'-'Lo' gas control to each burner. The burners are fitted with piezo ignited permanent pilot
and flame failure protection for each burner.
- Australia:
- New Zealand:
- United Kingdom:
Category: II
2H3P
(20, 30 / 37).
Flue Type: A
1.
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at 'High Flame'
setting. Operating pressure is ex-factory set and is not to be adjusted, apart from when converting between
gases, if required. Refer to ‘Gas Conversion’ Section in this manual for further details.
Natural Gas LP Gas (Propane)
CB6 CB9 CB6 CB9
Input Rating 66.0 MJ/hr 100.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure 0.95 kPa 2.60 kPa
Gas Connection
½" BSPT Male ¾" BSPT Male ½" BSPT Male ¾" BSPT Male
Propane (G31)
CB6 CB9 CB6 CB9
Heat Input (nett)
Nominal
18.0 kW 27.kW 18.0 kW 27.kW
Reduced
6.0 kW 9 kW 6.4 kW 9.6 kW
Gas Rate (nett)
Nominal
1.90 m
3
/hr 2.86 m
3
/hr 1.40 kg/hr 2.10 kg/hr
Reduced
0.63 m
3
/hr 0.95 m
3
/hr 0.50 kg/hr 0.75 kg/hr
Supply Pressure
20 mbar 30 / 37 mbar
Burner Operating Pressure (*)
10 mbar 26 mbar
Gas Connection
½" BSPT Male ¾" BSPT Male ½" BSPT Male ¾" BSPT Male
Natural Gas LP Gas
CB6 CB9 CB6 CB9
Input Rating 66.0 MJ/hr 100.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure
0.95 kPa 2.60 kPa
Gas Connection
½" BSPT Male ¾" BSPT Male ½" BSPT Male ¾" BSPT Male
Loading ...
Loading ...
Loading ...