SPS5000X Series User Manual
WWW.SIGLENT.COM 94
E.g: LIST:DELAy? CH1,1
Response:9.000000\n
Set the voltage rise slope for the specified number of steps
Command format: [:SOURce]:LIST:VOLTage:RISE:SLOPe <channel>,<step>,{<value> | MINimum |
MAXimum |DEFault}
Description: Set the voltage rise slope value of the selected channel steps in list mode
E.g: LIST:VOLTage:RISE:SLOPe CH1,1,160
Description: Set the voltage rise slope of step 1 of channel 1 to 160V / s
Command format: [:SOURce]:LIST:VOLTage:RISE:SLOPe? <channel>,<step>
Description: Obtain the voltage rise slope value of the selected channel steps in list
mode
E.g: LIST:VOLTage:RISE:SLOPe? CH1,1
Response: 160.000000\n
Set the voltage fall slope for the specified number of steps
Command format: [:SOURce]:LIST:VOLTage:FALL:SLOPe <channel>,<step>,{<value> | MINimum |
MAXimum |DEFault}
Description: Set the voltage fall slope value of the selected channel steps in list mode
E.g: LIST:VOLTage:FALL:SLOPe CH1,1,160
Description: Set the voltage fall slope of step 1 of channel 1 to 160V / s
Command format: [:SOURce]:LIST:VOLTage:FALL:SLOPe? <channel>,<step>
Description: Obtain the voltage fall slope value of the selected channel steps in list
mode
E.g: LIST:VOLTage:FALL:SLOPe? CH1,1
Response:160.000000\n
Set the current rise slope for the specified number of steps
Command format: [:SOURce]:LIST:CURRent:RISE:SLOPe <channel>,<step>,{<value> | MINimum |
MAXimum |DEFault}
Description: Set the current rise slope value of the selected channel steps in list mode
E.g: LIST:CURRent:RISE:SLOPe CH1,1,30
Description: Set the current rise slope of step 1 of channel 1 to 30A / s