WWW.SIGLENT.COM 85
Set OCP value
Command format: [:SOURce]:OCP <channel>,{<value> | MINimum | MAXimum |DEFault}
Description: Set the overcurrent value of the selected channel
E.g: :SOURce:OCP CH1,8
Description: Set the OCP value of CH1 to 8A
Command format: [:SOURce]:OCP? <channel>
Description: Get the overcurrent value of the selected channel
E.g: :SOURce:OCP? CH1
Response: 8.000000\n
Set OCP switch state
Command format: SYStem:OCP:STATe <channel>,{ON | OFF | 0 | 1}
Description: Set the ocp switch state of the selected channel
E.g: SYStem:OCP:STATe CH1, 1
Description: Set to open OCP function
Command format: SYStem:OCP:STATe? <channel>
Description: Get the ocp switch status of the selected channel
E.g: SYStem:OCP:STATe? CH1
Response: 1\n
Set the voltage rise slope
Command format: [:SOURce]:VOLTage:RISE:SLOPe <channel>,{<value> | MINimum | MAXimum |DEFault}
Description: Set the voltage rise slope value of the selected channel
E.g: :SOURce:VOLTage:RISE:SLOPe CH1,8
Description: Set the voltage rising slope of CH1 channel to 8V/s
Command format: [:SOURce]:VOLTage:RISE:SLOPe? <channel>
Description: Get the voltage rise slope value of the selected channel
E.g: :SOURce:VOLTage:RISE:SLOPe? CH1
Response: 23.000000\n
Set the voltage drop slope
Command format: [:SOURce]:VOLTage:FALL:SLOPe <channel>,{<value> | MINimum | MAXimum |DEFault}