4. Control Panel and LCD Operations
Messages in the LCD Explanation
Warning! Parallel UPS Config. Wrong Parallel UPS Configure error.
Warning! Battery Voltage Low Battery voltage is too low.
Warning! ID Conflict Power stage ID in conflict.
Warning! Redundancy Set Fail As stated.
Pre-Alarm! Line Voltage Fail Line voltage over range.
Pre-Alarm! Line Voltage Normal Line voltage recovered to normal.
Pre-Alarm! Line Frequency Unstable Line frequency over range.
Pre-Alarm! Line Frequency Normal Line frequency recovered to normal.
Pre-Alarm! Over Load Output Load over range.
Pre-Alarm! Load Normal Output Load recovered to normal.
Pre-Alarm! Load Unbalance Output Load unbalance.
4.4 History Record
Table 4.13: Warning List For Changing Important Settings
Item No. Description Item No. Description
1 Setup! Model Name 2 Setup! Turn On Password
3 Setup! Language 4 Setup! Change Turn On Password
5 Setup! Adjust Time 6 Setup! Nominal Power Display
7 Setup! System Installed Date 8 Setup! Output Voltage
9 Setup! System Last Maintain Date 10 Setup! Bypass Voltage Range
11 Setup! Battery Installed Date 12 Setup! Bypass Frequency Range
13 Setup! Battery Last Maintain Date 14 Setup! Converter Mode
15 Setup! Change Password 16 Setup! ECO Mode
17 Setup! Baud Rate 18 Setup! Bypass Mode
19 Setup! Audible Alarm 20 Setup! Auto-Restart
21 Setup! Factory Reset 22 Setup! Cold Start
23 Setup! EEPROM Reset 24 Setup! Battery Mode Delay Time
25 Setup! EPO Function 26 Setup! Shutdown Restore Time
27 Setup! Save Setting 28 Setup! Redundancy
29 Setup! Power Rating Setting 30 Setup! Charger Test
31 Setup! Nominal Battery Voltage 32 Setup! Battery Capacity in Ah
33 Setup! Maximum Charging Current 34 Setup! Battery Low Voltage
35 Setup! Battery Low Capacity 36 Setup! Battery Shutdown Voltage
37 Setup! Periodic Battery Test 38 Setup! Stop By Time
39 Setup! BATTERY Age Alert 40 Setup! Temperature Compensation
41 Setup! Charging Voltage 42 Setup! PRE-ALARM
43 Setup! UPS Parallel 44 Setup! Independent Battery
45 Setup! Auto-Restart Battery Voltage
Table 4.14: UPS Mode Changes
Item No. Description Item No. Description
1 UPS Mode! Power On Mode 2 UPS Mode! Standby Mode
3 UPS Mode! Bypass Mode 4 UPS Mode! Line Mode
5 UPS Mode! Battery Mode 6 UPS Mode! Battery Test Mode
7 UPS Mode! Fault Mode 8 UPS Mode! Converter Mode
9 UPS Mode! ECO Mode 10 UPS Mode! Shutdown Mode
11 UPS Mode! Un-Connection
Table 4.15: Control Action Execution
Item No. Description Item No. Description
1 Control! System Turn On 2 Control! System Turn Off
3 Control! Manual Battery Test 4 Control! Cancel Battery Test
5 Control! Turn To Bypass 6 Control! Shutdown Restore
7 Control! Cancel Shutdown 8 Control! Charger Turn On
9 Control! Charger Turn Off