IP Address Conicted The IP address of current device is same as that of other device in
the network.
Illegal Login Incorrect user name or password is entered.
3.
Refer to
Linkage Method Sengs for seng linkage method.
4.
Click Save.
6.1.4 Set Alarm Input
Alarm signal from the external device triggers the corresponding acons of the current device.
Before You Start
Make sure the external alarm device is connected. See Quick Start Guide for cable connecon.
Steps
1.
Go to Conguraon → Event → Basic Event → Alarm Input .
2.
Check Enable Alarm Input Handling.
3.
Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4.
Refer to Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
5.
Click Copy to... to copy the sengs to other alarm input channels.
6.
Click Save.
6.1.5 Set Video Quality Diagnosis
When the video quality of the device is abnormal and the alarm linkage is set, the alarm will be
triggered automacally.
Steps
1.
Go to Conguraon → Event → Basic Event → Video Quality Diagnosis .
2.
Select Diagnosis Type.
3.
Set the corresponding parameters.
Alarm Detecon Interval
The me interval to detect the excepon.
Sensivity
The higher the value is, the more easily the excepon will be detected, and the higher
possibility of misinformaon would be.
Alarm Delay Times
The device uploads the alarm when the alarm reaches the set number of mes.
4.
Check Enable, and the selected diagnosis type will be detected.
5.
Set arming schedule. See
Set Arming Schedule .