31-5000553 Rev. 1 5
ENGLISH
READ AND SAVE THESE INSTRUCTIONS
FOR MORE HELP, VISIT HAIERAPPLIANCES.COM OR CALL THE CONSUMER HELP LINE AT 877-337-3639.
Grounding wire should be connected to the ground buss in
the circuit breaker panel. The grounding wire should not
be connected to gas pipes, water pipes, lightening rods or
the telephone grounding wire. Improper grounding may
cause electric shock.
A circuit breaker protecting the equipment wiring must be
installed. Failure to properly protect equipment wiring can
cause damage, personal injury or death.
After installation, the air conditioning equipment should
be powered on and pass an electric currentleakage lest.
Water vapor or spray can be blown off the coil surface
if the ambient humidity is greater than 80%, the
condensate drain opening is blocked, the filter becomes
çìõ÷üòõ÷ëèäìõĩòúåèæòðèöõèö÷õìæ÷èçéòõäñüõèäöòñé
the pipe is bent repeatedly at the same place, it will break.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT – Save these instructions for local inspectors use.
IMPORTANT – Observe all governing codes and ordinances.
Note to installer – Be sure to leave these instructions with the Consumer.
Note to consumer – Keep these instructions for future reference.
Skill level – A licensed certified technician (to handle refrigerant R-410A, recovery, etc) and a qualified electrician are
required for installation and service of this split heat pump system.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the limited warranty.
For personal safety, this system must be properly grounded.
Protective devices (fuses or circuit breakers) acceptable for installation are specified on the nameplate of each unit.
Make sure to avoid wiring or plumbing inside the wall when installing.
CAUTION
Aluminum electrical wiring may present special problems - consult a qualified electrician.
When the unit is in the STOP position, there is still voltage to the electrical controls.
CAUTION
IMPORTANT SAFETY INFORMATION