B. Cleaning and Sanitizing Instructions
The appliance must be cleaned and sanitized at least twice a year. More frequent
cleaning and sanitizing may be required in some conditions.
WARNING
To prevent injury to individuals and damage to the appliance, do not use
ammonia type cleaners.
• Carefully follow any instructions provided with the cleaning and sanitizing
solutions.
Always wear liquid-proof gloves and goggles to prevent the cleaning and
sanitizing solutions from coming into contact with skin or eyes.
After cleaning and sanitizing, do not use ice made from the cleaning and
sanitizing solutions. Be careful not to leave any solution on the parts or in the
dispenser unit/ice storage bin.
1. Cleaning Solution
Dilute 9.6 . oz. (0.29 l) of Hoshizaki "Scale Away" with 1.6 gal. (6.0 l) of warm water.
This is a minimum amount. Make more solution if necessary. IMPORTANT! For safety
and maximum effectiveness, use the solution immediately after dilution.
2. Cleaning Procedure
1) Close the icemaker water supply line shut-off valve.
2) After the gear motor starts, remove the front panel. Move the power switch to the "OFF"
position. Move the control switch to the "DRAIN" position, then move the power switch
back to the "ON" position. Replace the front panel in its correct position.
3) Allow the water system to drain completely.
4) Remove the front and top panels. Move the power switch to the "OFF" position, then
unplug the icemaker from the electrical outlet.
5) Remove all of the ice from the dispenser unit/ice storage bin. WARNING! If on a
dispenser unit, turn off the dispenser unit power supply after dispensing the ice.
6) Remove the spout spring, then open the spout cover. See Fig. 14.
7) Pour the cleaning solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to run through the overow hose on the
reservoir.
Note: If there is excess scale on the extruding head, ll the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between the
reservoir and evaporator assembly to block ow. Pour additional cleaning solution over
the extruding head until the evaporator assembly is completely full.
8) Close the spout cover and replace the spout spring in its correct position.
9) Allow the icemaker to sit for 10 minutes before operation. If you placed a clamp on the
reservoir hose in step 7, remove it before operation.