Hoshizaki FS1501MLJC FS-1501MLJ-C 30" Serenity Series Cubelet Ice Machine

Instruction Manual - Page 22

For FS1501MLJC.

PDF File Manual, 36 pages, Read Online | Download pdf file

FS1501MLJC photo
Loading ...
Loading ...
Loading ...
22
G. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
At startup, conrm that all internal and external connections are free of leaks.
The remote condensing unit must have power for a minimum of 4 hours prior to
startup to prevent compressor damage.
1) Make sure the remote condensing unit has had power for a minimum of 4 hours.
2) Open the water supply line shut-off valve.
3) If removed, replace all panels except the front panel in their correct positions. If not
already removed, remove the front panel.
4) Make sure the icemaker power switch is in the "OFF" position. Plug the icemaker into
the electrical outlet. Move the control switch to the "ICE" position, then move the power
switch to the "ON" position to start the automatic icemaking process.
5) Replace the front panel in its correct position.
6) Once the icemaker starts to produce ice, allow it to run for another 30 minutes.
7) Remove the front panel.
8) Move the power switch to the "OFF" position. Move the control switch to the "DRAIN"
position, then move the power switch back to the "ON" position. Replace the front panel
in its correct position. Allow the water system to drain for 5 minutes.
9) Remove the front panel.
10) Move the power switch to the "OFF" position, then unplug the icemaker from the
electrical outlet.
11) Pour warm water into the dispenser unit/ice storage bin and melt any remaining ice.
Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly
after cleaning.
12) Conrm bin control operation. See "II.H. Bin Control Check."
Loading ...
Loading ...
Loading ...