external pump starts to drain the water out. After the pump drained, the dehumidifier
will automatically restart.
When the dehumidifier displays an E5 error after confirming the compatibility with the
pump signal, it typically because the drain hose or the water pump is blocked. Please
turn off the dehumidifier and troubleshoot, and then restart the dehumidifier after
troubleshooting.
If the external pump output signal NOT compatible with our dehumidifier
After connecting the output signal cable to the dehumidifier, the dehumidifier does
not work and displays an E5 error and the pump does not work, which indicates the
external pump output signal is not compatible with our dehumidifier.
In this case, please disconnect the signal cable from the dehumidifier, turn off the
dehumidifier and then restart the dehumidifier. The dehumidifier will automatically
eliminate the Error code and resume working.
8. Smart Functions
(1) 3 Minutes Compressor Delay Mechanism
To avoid any damage to the dehumidifier, the dehumidifier will not start operation
following a complete cycle until after 3 minutes. Operation will automatically start
after 3 minutes. In other word, if you turn the dehumidifier off and then restart it
immediately, the compressor will not kick in until 3 minutes later. During this period,
you can see the RUNNING icon flashing on the LCD screen until the compressor kicks
in.