User Manual Rheem 7386782 REPL PWA RHW42

Documents for Rheem 7386782

The following documents are available:
User Manual
  • Installation Guide & Owners Manual Electronic Control Board PWA Replacement Rheem RHW42 - (English) Read Online | Download pdf
Photos
7386782 photo

Installation Guide & Owners Manual Electronic Control Board PWA Replacement Rheem RHW42

For 7386782.

ELECTRONIC CONTROL BOARD (PWA) REPLACEMENT
7386813 (Rev. A 10/6/20)
1. Unplug the water softener’s power supply from electrical power.
2. Remove the top cover and salt lid to expose the valve.
3. Unsnap the faceplate from its support to expose the Electronic
Control Board.
4. Unplug the wiring connections from the back of the old Electronic
Control Board (See Figure 2) and remove the old board’s status light
from its holder in the faceplate.
5. Carefully remove the old board by unsnapping it from its retainer tabs.
6. Carefully snap the new Electronic Control Board into the retainer tabs.
7. Reconnect the wiring to the new board (See Figure 2) and insert the
new board’s status light into the holder in the faceplate.
IMPORTANT: BE SURE THE VALVE CAM INDICATES “SERVICE”
P
OSITION (See Figure 1) WHEN REPLACING THE ELECTRONIC
CONTROL BOARD (PWA), TO ASSURE BOTH VALVE AND PWA
ARE ORIENTED, OR TIMED, TO THE SAME CYCLE. If the valve is
not in Service position, see step 12 below.
NOTE: When installing the electronic control board (PWA) on the face-
plate, use care not to twist the circuit board, or force it onto the
mounting pegs. Twisting could damage the printed circuits, or break the
display glass.
8. Snap the faceplate back into its holder, being careful
not to pinch any wires.
9. Plug the power supply into the electrical outlet.
A model code (rH42) and a software version number
(example: r4.2) briefly appear in the faceplate
display. Then the words “SET TIME” appear and
“12:00 PM” begins to flash.
10. Press the
r UP and s DOWN buttons to set the
present time. Up moves the display ahead; down
sets the time back.
NOTE: Press buttons and quickly release to slowly
advance the display. Hold the buttons down for
fast advance.
11. Press the SELECT button, and continue program-
ming hardness, recharge start time, salt type, and
salt level. For details, consult your owner’s
manual. When you have finished programming the
controller, the time appears on the display, but is
not flashing.
12. If the valve is not in Service position, press the
RECHARGE button and hold for 3 seconds to start
a recharge cycle. The display will flash “RECHARGE
NOW”. In about 2 hours the recharge cycle will be
complete and the valve and electronic control
board will be properly oriented together.
NOTE: To save time, use the manual advance proce-
dures to properly time and check operation.
See “Troubleshooting” in the owner’s manual.
If you have a wireless account:
13. The new Electronic Control Board will not be auto-
matically recognized, so you must register it to your
account as a new device. Open the iQua™ app
and log into your account.
14. Place the controller into Connect Mode, as shown
in Figure 3. “Conn” appears in the display.
15. On the app’s “Devices” screen, press the “Add
Device” button. Follow the instructions in the app
(or your water softener owner’s manual) to connect
the system to the cloud via your home’s wireless
router, and register the system to your account.
Figure 3
P
osition markers
(valve in service)
CAM
MOTOR
Figure 1
Back of Electronic
Control Board
Valve
Motor
Power
Supply
Turbine
Sensor
Valve Position
Switch
Auxiliary
Output
Motorized
Water Shutoff
Valve
Figure 2
16. Delete the old system from your account (this is the old
Electronic Control Board that you took out of the softener).
In the app, go to “Device Management”, then “Device
Information”, identify the old device and delete it.
Status
Light
Press both
UP and
DOWN
buttons,
and hold for
3 seconds,
to put into
Connect Mode